Medical Engineering & Physics
Volume 32, Issue 9 , Pages 998-1008, November 2010

Influence of mesh density, cortical thickness and material properties on human rib fracture prediction

Center for Applied Biomechanics, University of Virginia, 1011 Linden Avenue, Charlottesville, VA 22902, USA

Received 13 April 2010; received in revised form 28 June 2010; accepted 29 June 2010. published online 02 August 2010.

Abstract 

The purpose of this paper was to investigate the sensitivity of the structural responses and bone fractures of the ribs to mesh density, cortical thickness, and material properties so as to provide guidelines for the development of finite element (FE) thorax models used in impact biomechanics. Subject-specific FE models of the second, fourth, sixth and tenth ribs were developed to reproduce dynamic failure experiments. Sensitivity studies were then conducted to quantify the effects of variations in mesh density, cortical thickness, and material parameters on the model-predicted reaction force–displacement relationship, cortical strains, and bone fracture locations for all four ribs. Overall, it was demonstrated that rib FE models consisting of 2000–3000 trabecular hexahedral elements (weighted element length 2–3mm) and associated quadrilateral cortical shell elements with variable thickness more closely predicted the rib structural responses and bone fracture force–failure displacement relationships observed in the experiments (except the fracture locations), compared to models with constant cortical thickness. Further increases in mesh density increased computational cost but did not markedly improve model predictions. A ±30% change in the major material parameters of cortical bone lead to a −16.7 to 33.3% change in fracture displacement and −22.5 to +19.1% change in the fracture force. The results in this study suggest that human rib structural responses can be modeled in an accurate and computationally efficient way using (a) a coarse mesh of 2000–3000 solid elements, (b) cortical shells elements with variable thickness distribution and (c) a rate-dependent elastic–plastic material model.

Keywords: Cortical thickness, Finite element, Rib fracture, Sensitivity studies

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(10)00142-6

doi:10.1016/j.medengphy.2010.06.015

Medical Engineering & Physics
Volume 32, Issue 9 , Pages 998-1008, November 2010