Medical Engineering & Physics
Volume 32, Issue 8 , Pages 914-920, October 2010

Fluid transfer as a mechanism leading to endotension

  • A. Gebert de Uhlenbrock

      Affiliations

    • Biomechanics Section, TUHH Hamburg University of Technology, Denickestrasse 15, D-21073 Hamburg, Germany
    • Corresponding Author InformationCorresponding author. Tel.: +49 040 42878 3386; fax: +49 040 42878 2996.
    web address
  • ,
  • C. Wintzer

      Affiliations

    • Department of Vascular & Visceral Surgery, General Hospital Hamburg, Hamburg, Germany
  • ,
  • H. Imig

      Affiliations

    • German Society for Endovascular & Vascular Surgery, Berlin, Germany
  • ,
  • M.M. Morlock

      Affiliations

    • Biomechanics Section, TUHH Hamburg University of Technology, Denickestrasse 15, D-21073 Hamburg, Germany

Received 28 May 2009; received in revised form 15 April 2010; accepted 27 June 2010. published online 02 August 2010.

Abstract 

Some abdominal aortic aneurysms bridged with a minimally invasively introduced stent graft prosthesis increase in size without any diagnosable evidence of endoleakage (endotension). There are three possible pathways proposed through which undetectable low rates of blood flow may cause an aneurysm sac to be refilled: through the thrombus at the prosthesis attachment sites, through the clotted collaterals and through the clotted stent graft wall. If the inflow is more rapid than any drainage through the wall of the aneurysm is re-pressurised. However, critical magnitudes for the permeability of the clotted graft and the geometry of the thrombus at the aneurysm, necessary to inhibit endotension, are not known. The aim of this study was to determine which boundary conditions prevent endotension.

An analytical model based on Darcy's Law was used to estimate the pressure in the aneurysm sac due to fluid transfer. Experimentally determined time- and pressure-dependent permeability of red and intraluminal thrombus, and of clotted graft materials were input into the model. The computational analysis showed that endotension is unlikely to be caused by fluid transfer from the collaterals or via the prosthesis attachment sites, but rather due to flow through the stent graft wall. Based on this study it can be stated that grafts with a permeability below 2e−13mm2 should diminish the occurrence of endotension.

Keywords: EVAR, Stent graft, Endotension, Abdominal aneurysm, Thrombus

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(10)00136-0

doi:10.1016/j.medengphy.2010.06.009

Medical Engineering & Physics
Volume 32, Issue 8 , Pages 914-920, October 2010