Volume 32, Issue 7 , Pages 760-765, September 2010

The patellar tendon bar! Is it a necessary feature?

  • N.A. Abu Osman

      Affiliations

    • Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia
    • Corresponding Author InformationCorresponding author. Tel.: +60 3 79674581; fax: +60 3 79674579.
  • ,
  • W.D. Spence

      Affiliations

    • Bioengineering Unit, University of Strathclyde, Glasgow, UK
  • ,
  • S.E. Solomonidis

      Affiliations

    • Bioengineering Unit, University of Strathclyde, Glasgow, UK
  • ,
  • J.P. Paul

      Affiliations

    • Bioengineering Unit, University of Strathclyde, Glasgow, UK
  • ,
  • A.M. Weir

      Affiliations

    • Westmarc, Southern General Hospital, Glasgow, UK

Received 14 September 2009; received in revised form 27 April 2010; accepted 29 April 2010. published online 08 June 2010.

Abstract 

The purpose of this investigation was to vary the load on the patellar tendon bar and to study the subsequent effect this has on the pattern of the pressure distribution at the stump–socket interface. Ten male subjects from the Southern General Hospital in Glasgow, UK participated in this study. Measuring systems utilising strain gauge and electrohydraulic technologies were designed, developed and constructed to enable pressure measurements to be conducted. One transducer, the patellar tendon (PT) transducer, was attached to the patellar tendon bar of the socket such that the patellar tendon bar was capable of being translated by ±10mm towards or away from the tendon. The results of this study showed that the position of the patellar tendon bar had no significant effect on the pressure distribution around the socket indicating that it is an unnecessary feature, which, we propose, may be eliminated during manufacture of a trans-tibial socket.

Keywords: Trans-tibial, Pressure distribution, Patellar tendon bar, Stump, Pressure, Patellar tendon bearing socket

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(10)00094-9

doi:10.1016/j.medengphy.2010.04.020

Medical Engineering & Physics
Volume 32, Issue 7 , Pages 760-765, September 2010