Medical Engineering & Physics
Volume 32, Issue 2 , Pages 155-160, March 2010

Compressive and tensile properties of articular cartilage in axial loading are modulated differently by osmotic environment

Department of Physics, University of Kuopio, POB 1627, FI-70211 Kuopio, Finland

Received 7 October 2008; received in revised form 23 September 2009; accepted 4 November 2009. published online 02 December 2009.

Abstract 

Aims of the present study were to test the hypotheses that (1) the compressive properties of articular cartilage are affected more by changes in the medium ionic concentration than the tensile properties, (2) collagen network controls the compression–tension nonlinearity of articular cartilage, and (3) proteoglycan (PG) and collagen contents are primary determinants of the compressive and tensile properties of cartilage, respectively. These hypotheses were experimentally tested by axial compressive and tensile tests (perpendicular to the cartilage surface) of bovine articular cartilage samples immersed in 0.005M (n=6), 0.15M (n=12) and 1.0M (n=6) saline solutions. Compressive and tensile behaviour was analyzed by a nonlinear fibril-reinforced poroelastic model. Tissue PG and collagen contents were measured using Fourier transform infrared imaging spectroscopy (FT-IRIS). The compressive modulus of cartilage varied significantly (n=6, p<0.05) as the medium concentration changed. The tensile modulus changed significantly only as the medium concentration was reduced from 0.15 to 0.005M (n=6, p<0.05). The fibril-reinforced poroelastic model with stiff, nonlinear collagen fibrils predicted the experimentally measured compression–tension nonlinearity of cartilage. Tissue PG and collagen contents accounted for the compressive and tensile properties of cartilage.

Keywords: Articular cartilage, Biomechanics, Osmolarity, Fibril reinforcement, Spectroscopy, Compression, Tension

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00236-7

doi:10.1016/j.medengphy.2009.11.004

Medical Engineering & Physics
Volume 32, Issue 2 , Pages 155-160, March 2010