A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model

  • Panagiotis E. Chatzistergos

      Affiliations

    • Unit of Biomechanics, Department of Mechanics, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, Theocaris Building, 157-73 Attiki, Greece
  • ,
  • Evangelos A. Magnissalis

      Affiliations

    • Laboratory for the Research of the Musculoskeletal System (LRMS), University of Athens, KAT Hospital, Kifissia, Athens, Greece
  • ,
  • Stavros K. Kourkoulis

      Affiliations

    • Unit of Biomechanics, Department of Mechanics, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, Theocaris Building, 157-73 Attiki, Greece
    • Corresponding Author InformationCorresponding author. Tel.: +30 210 7721263; fax: +30 210 7721301.

Received 17 June 2009; received in revised form 14 September 2009; accepted 2 November 2009. published online 30 November 2009.

Abstract 

The present study aims to the design of a finite-element model simulating accurately the pullout behaviour of cylindrical pedicle screws and predicting their pullout force. Three commercial pedicle screws, subjected to pure pullout from synthetic bone, were studied experimentally. The results were used for the design, calibration and validation of a finite-element model. Special attention was paid to the accurate simulation of the failure inside the host material under shear. For this purpose, a bilinear cohesive zone material model was adopted, controlling the mode-II debonding of neighbouring elements in the vicinity of the screw. Comparison between experimental and numerical results proved that the implementation of this approach can significantly enhance the accuracy of the numerical simulation of a screw's mechanical behaviour under pure pullout loads. The numerical model was used for the parametric study of various factors affecting the pullout performance of a cylindrical pedicle screw. It was concluded that the major parameter influencing the pullout force is the outer radius (increasing its value by 36% increases the pullout force by 34%). The influence of the purchase length of the screw is of similar quantitative nature. The respective dependence on the thread inclination, depth and pitch was significantly weaker.

Keywords: Bone screws, Pullout force, Finite element analysis, Cohesive zone, Synthetic bone

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00235-5

doi:10.1016/j.medengphy.2009.11.003

Medical Engineering & Physics
Volume 32, Issue 2 , Pages 145-154, March 2010