Medical Engineering & Physics
Volume 31, Issue 8 , Pages 930-936, October 2009

Development of a reinforced PMMA-based hip spacer adapted to patients’ needs

  • T. Thielen

      Affiliations

    • Research Unit in Engineering Sciences, University of Luxembourg, Luxembourg
    • Corresponding Author InformationCorresponding author at: Université du Luxembourg, Faculté des Sciences, de la Technique et de la Communication, 6, rue Richard Coudenhove-Kalergi, L-1359 Luxembourg-Kirchberg, Luxembourg. Tel.: +352 46 66 44 5422; fax: +352 46 66 44 5620.
  • ,
  • S. Maas

      Affiliations

    • Research Unit in Engineering Sciences, University of Luxembourg, Luxembourg
  • ,
  • A. Zuerbes

      Affiliations

    • Research Unit in Engineering Sciences, University of Luxembourg, Luxembourg
  • ,
  • D. Waldmann

      Affiliations

    • Research Unit in Engineering Sciences, University of Luxembourg, Luxembourg
  • ,
  • K. Anagnostakos

      Affiliations

    • Orthopaedic Department of the Saarland University Hospital, Homburg (Saar), Germany
  • ,
  • J. Kelm

      Affiliations

    • Orthopaedic Department of the Saarland University Hospital, Homburg (Saar), Germany

Received 14 October 2008; received in revised form 11 May 2009; accepted 13 May 2009. published online 12 June 2009.

Abstract 

Two-stage reimplantation using an interval hip prosthesis (spacer) of antibiotic-impregnated bone cement has become a well-accepted method to eradicate infection and prevent limb shortening. However, custom made as well as prefabricated spacers share a weakness of limited strength and hence several fractures of spacers have been observed, even for partial weight bearing. The purpose of this study was therefore to improve the strength of the custom made spacer, used at the Orthopaedic Department of the Saarland University Hospital (Germany). As the material strength of bone cement is limited, several reinforced spacers with a metal core consisting of titanium grade two have been developed and investigated. Loading procedure was close to the ISO 7206/4, though small adaptation was made. An inserted rod of titanium grade two increased the collapse load up to 1000–1300N, but considering a maximum expected load of about three times the body weight, still below the required value. A “full-stem” reinforced spacer, i.e. spacer with a titanium endoskeleton and a minimum of 2–3mm PMMA-coating in order to assure drug release, provides a mobile and functional joint through the treatment course. Those with 8mm thickness of titanium endoskeleton endured up to one million load cycles in a load range of 300–2300N. To give further support for individual cases a meaningful S–N curve for this device was determined.

Keywords: Total hip arthroplasty, Spacer fracture, Infection, PMMA, Reinforcement

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00117-9

doi:10.1016/j.medengphy.2009.05.004

Medical Engineering & Physics
Volume 31, Issue 8 , Pages 930-936, October 2009