Medical Engineering & Physics
Volume 31, Issue 7 , Pages 806-815, September 2009

Biomechanical study of mandible bone supporting a four-implant retained bridge:

Finite element analysis of the influence of bone anisotropy and foodstuff position

  • A.S. Bonnet

      Affiliations

    • Laboratory of Mechanics, Biomechanics, Polymers and Structures (LaBPS), ENIM, Ile du Saulcy 57045 Metz, France
    • Corresponding Author InformationCorresponding author. Tel.: +33 3 87 34 42 64; fax: +33 3 87 34 69 35.
  • ,
  • M. Postaire

      Affiliations

    • Department of Prosthetic Dentistry, René Descartes University Paris V, 92120 Montrouge, France
  • ,
  • P. Lipinski

      Affiliations

    • Laboratory of Mechanics, Biomechanics, Polymers and Structures (LaBPS), ENIM, Ile du Saulcy 57045 Metz, France

Received 29 July 2008; received in revised form 9 February 2009; accepted 11 March 2009. published online 23 April 2009.

Abstract 

Purpose The aim of this work was to study the biomechanical behavior of a “All-on-four” implant-supported prosthesis through a finite element analysis using either isotropic or anisotropic properties of bone. The influence of foodstuff position during mastication was also analysed.

Materials and methods A three-dimensional finite element model of a mandible with a prosthesis supported by four implants was developed. The geometry of the edentulous mandible and prosthesis was generated from computed tomography. Four MKIII® implants (two vertical and two tilted) were modeled. The bone elastic properties used in the anisotropic simulations were orthotropic. The comparison of isotropic and anisotropic models was carried out in the loading condition of mastication with a foodstuff positioned on molar. Three distinct configurations, corresponding to three foodstuff positions, were then studied. MSC/Marc code was used to perform all computations.

Results Significant differences in stress, strain, and strain energy densities were found in the comparison of isotropic and orthotropic models. Molar position was revealed to be the most critical one, from a stress and strain level point of view, for implants and framework and consequently for peri-implant bone. It was also observed that implant tilting leads to high stress concentrations in bone for the “All-on-four” concept.

Conclusion This study showed that the anisotropic behaviour of bone cannot be neglected in the numerical simulations. The actual design of the prosthesis is not optimal concerning the capacity of all metallic parts to support loads. Finally, it was demonstrated that the tilting of implants induced a high stress level at bone-implant interface.

Keywords: Dental implants, Mandible anisotropy, Finite element model, Prosthesis design

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00075-7

doi:10.1016/j.medengphy.2009.03.004

Medical Engineering & Physics
Volume 31, Issue 7 , Pages 806-815, September 2009