« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 6
, Pages 695-704
, July 2009
Development of a new dynamometer for measuring grip strength applied on a cylindrical handle
References
- . Musculoskeletal Disorders and Workplace Factors: A Critical Review of Epidemiologic Evidence for Work-Related Musculoskeletal Disorders of the Neck, Upper Extremity, and Low Back. Cincinnati, OH, USA: NIOSH Publication, U.S. Department of Health and Human Services, National Institute for Occupational Safety and Health; 1997;p. 97–141
- . The Occupational Ergonomics Handbook. New York, USA: CRC Press; 1999;
- . Medical aspects of the hand-arm vibration syndrome. International Journal of Industrial Ergonomics. 1990;6(1):61–73
- ISO 5349-1. Mechanical vibration—Measurement and evaluation of human exposure to hand-transmitted vibration–Part 1: General guidelines. International Organization of Standard, Geneva, Switzerland; 2001.
- . Comparison of different approaches for ergonomic job evaluation for predicting risk of upper extremity disorders. IEA 94. Occupational Health and Safety. 1994;2:
- . Occupational factors and the carpal tunnel syndrome. American Journal of Industrial Medicine. 1987;11(3):343–358
- . Ergonomics of hand tools. In: Karwowski W, Marras WS editor. The Occupational Ergonomics Handbook. New York, USA: CRC Press; 1999;p. 461–478
- . Hand tools: design and evaluation. In: Karwowski W, Marras WS editor. The Occupational Ergonomics Handbook. New York, USA: CRC Press; 1999;p. 851–864
- . Hand-grip force in lumberjacks: Two-year follow-up. International Archives of Occupational and Environmental Health. 1986;58:203–208
- . Functional outcomes following surgical repair of wrist extensor tendons. British Journal of Plastic Surgery. 2003;56:120–124
- . Handgrip strength and hand dimensions in young handball and basketball players. The Journal of Strength and Conditioning Research. 2007;21(3):923–929
- . Development of a hand dynamometer for the control of manually applied forces. Journal of Manipulative and Physiological Therapeutics. 2006;29(4):297–304
- . A linear force-summing hand dynamometer independent of point of application. Applied Ergonomicsx. 1991;22(5):339–345
- . An Investigation on the Relationship between Grip, Push, and Contact Forces Applied to a Tool Handle. International Journal of Industrial Ergonomics. 2004;34:507–518
- . Grip force vectors for varying handle diameters and hand sizes. Human Factors. 2004;46:244–251
- . A new approach to characterize grip force applied to a cylindrical handle. Medical Engineering and Physics. 2008;30:20–33
- . A Novel force transducer for the measurement of grip force. Journal of Biomechanics. 2001;34:125–128
- . Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. Journal of Biomedical Engineering. 1987;9:313–320
- . Measuring hand-grip force using a new application of strain gauges. Medical and Biological Engineering & Computing. 1981;19:127–128
- . The effect of torque direction and cylindrical handle diameter on the coupling between the hand and cylindrical handle. Journal of Biomechanics. 2007;40:3236–3243
- . Functional handgrip test to determine the coefficient of static friction at the hand/handle interface. Ergonomics. 2002;45:717–731
- . Contact pressure distribution at hand-handle interface: role of hand forces and handle size. International Journal of Industrial Ergonomics. 2005;35:267–286
- . Normal digital contribution to grip strength assessed by a computerized digital dynamometer. Journal of the British Society for Surgery of the Hand. 1998;23(2):162–166
☆ Disclamer: The content of this publication does not necessarily reflect the views or policies of the National Institute for Occupational Safety and Health (NIOSH), nor does mention of trade names, commercial products, or organizations imply endorsement by the U.S. Government.
PII: S1350-4533(09)00051-4
doi: 10.1016/j.medengphy.2009.01.009
« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 6
, Pages 695-704
, July 2009