Medical Engineering & Physics
Volume 31, Issue 6 , Pages 695-704, July 2009

Development of a new dynamometer for measuring grip strength applied on a cylindrical handle

Engineering & Control Technology Branch, National Institute for Occupational Safety and Health, 1095 Willowdale Road, MS L-2027, Morgantown, West Virginia 26505, USA

Received 10 October 2008; received in revised form 23 January 2009; accepted 28 January 2009. published online 02 March 2009.

Abstract 

The objective of this study is to enhance the understanding of the hand grip force applied to a cylindrical handle and to develop a new dynamometer for measuring maximum grip force or grip strength. Specifically, a 40mm instrumented cylindrical handle with six measuring arms was developed. A theoretical model was proposed and used to analyze the principle of the measurement. Human test subjects were used in conducting two sets of experiments to evaluate the handle and to assess the measurement method. This study confirmed that some friction force exists in the grip-only action, but its level is not comparable with the normal force. This study also found that the friction force can stabilize the grip action and marginally increase the grip strength. No reliable correlation between the grip strengths measured with the 40mm cylindrical handle and Jamar handle with a 47.6mm span was observed. This suggests that grip strength measured with Jamar handle may not be reliably applicable to the design and risk assessment of some tools or machines with cylindrical handles. In contrast, the cylindrical handle proved to be able to determine the overall grip strength for a subject, as well as show the grip force distribution around the circumference of the handle. The handle is accurate with less than 4% error, and it demonstrates that the measurement is independent of the loading position along the handle. Therefore, this study concluded that this new dynamometer is suitable for measuring grip strength with sufficient precision.

Keywords: Grip force, Grip strength, Hand force, Instrumented handle, Dynamometer

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Disclamer: The content of this publication does not necessarily reflect the views or policies of the National Institute for Occupational Safety and Health (NIOSH), nor does mention of trade names, commercial products, or organizations imply endorsement by the U.S. Government.

PII: S1350-4533(09)00051-4

doi:10.1016/j.medengphy.2009.01.009

Medical Engineering & Physics
Volume 31, Issue 6 , Pages 695-704, July 2009