Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

  • Marcel van’t Veer

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
    • Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands
    • Both authors contributed equally to the study.
    • Corresponding Author InformationCorresponding author at: Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands. Tel.: +31 402397004; fax: +31 402464837.
  • ,
  • Maartje C.F. Geven

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
    • Both authors contributed equally to the study.
  • ,
  • Marcel C.M. Rutten

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
  • ,
  • Arjen van der Horst

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
  • ,
  • Wilbert H. Aarnoudse

      Affiliations

    • Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands
  • ,
  • Nico H.J. Pijls

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
    • Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands
  • ,
  • Frans N. van de Vosse

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands

Received 30 June 2008 ,Revised 23 January 2009 ,Accepted 25 January 2009.

References 

  1. de Bruyne B, Bartunek J, Sys SU, Pijls NH, Heyndrickx GR, Wijns W. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation. 1996;94(8):1842–1849
  2. Pijls NH. Optimum guidance of complex PCI by coronary pressure measurement. Heart. 2004;90(9):1085–1093
  3. Aarnoudse W, van den Berg P, van de Vosse FN, Geven M, Rutten M, Van Turnhout M, et al. Myocardial resistance assessed by guidewire-based pressure-temperature measurement: in vitro validation. Catheter Cardiovasc Interv. 2004;62(1):56–63
  4. Fearon WF, Balsam LB, Farouque HM, Caffarelli AD, Robbins RC, Fitzgerald PJ, et al. Novel index for invasively assessing the coronary microcirculation. Circulation. 2003;107(25):3129–3132
  5. White CW. Clinical applications of Doppler coronary flow reserve measurements. Am J Cardiol. 1993;71(14):10D–16D
  6. Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol. 1954;6(12):731–744
  7. Buchi M, Jenni R. Measurement of flow velocity in the coronary circulation: requirements and pitfalls. Semin Interv Cardiol. 1998;3(1):45–50
  8. Barbato E, Aarnoudse W, Aengevaeren WR, Werner G, Klauss V, Bojara W, et al. Validation of coronary flow reserve measurements by thermodilution in clinical practice. Eur Heart J. 2004;25(3):219–223
  9. Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol. 1971;27(4):392–396
  10. de Bruyne B, Pijls NH, Smith L, Wievegg M, Heyndrickx GR. Coronary thermodilution to assess flow reserve: experimental validation. Circulation. 2001;104(17):2003–2006
  11. Pijls NH, de Bruyne B, Smith L, Aarnoudse W, Barbato E, Bartunek J, et al. Coronary thermodilution to assess flow reserve: validation in humans. Circulation. 2002;105(21):2482–2486
  12. Ganz W, Tamura K, Marcus HS, Donoso R, Yoshida S, Swan HJ. Measurement of coronary sinus blood flow by continuous thermodilution in man. Circulation. 1971;44(2):181–195
  13. Mathey DG, Chatterjee K, Tyberg JV, Lekven J, Brundage B, Parmley WW. Coronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow. Circulation. 1978;57(4):778–786
  14. Weisse AB, Regan TJ. A comparison of thermodilution coronary sinus blood flows and krypton myocardial blood flows in the intact dog. Cardiovasc Res. 1974;8(4):526–533
  15. Aarnoudse W, van’t Veer M, Pijls NH, Ter Woorst J, Vercauteren S, Tonino P, et al. Direct volumetric blood flow measurement in coronary arteries by thermodilution. J Am Coll Cardiol. 2007;50(24):2294–2304
  16. Geven MC, Bohte VN, Aarnoudse WH, van den Berg PM, Rutten MC, Pijls NH, et al. A physiologically representative in vitro model of the coronary circulation. Physiol Meas. 2004;25(4):891–904
  17. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–310
  18. Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995;346:1085–1087