Medical Engineering & Physics
Volume 31, Issue 4 , Pages 470-476, May 2009

Probabilistic analysis of an uncemented total hip replacement

Bioengineering Research Group, School of Engineering Sciences, University of Southampton, Southampton SO17 1BJ, United Kingdom

Received 28 January 2008; received in revised form 13 January 2009; accepted 15 January 2009. published online 17 February 2009.

Abstract 

This paper describes the application of probabilistic design methods to the analysis of the behaviour of an uncemented total hip replacement femoral component implanted in a proximal femur. Probabilistic methods allow variations in factors which control the behaviour of the implanted femur (the input parameters) to be taken into account in determining the performance of the construct. Monte Carlo sampling techniques were applied and the performance indicator was the maximum strain in the bone. The random input parameters were the joint load, the angle of the applied load and the material properties of the bone and the implant. Two Monte Carlo based simulations were applied, direct sampling and latin hypercube sampling. The results showed that the convergence of the mean value of the maximum strain improved gradually as a function of the number of simulations and it stabilised around a value of 0.008 after 6200 simulations. A similar trend was observed for the cumulative distribution function of the output. The strain output was most sensitive to the bone stiffness, followed very closely by the magnitude of the applied load. The application of latin hypercube sampling with 1000 simulations gave similar results to direct sampling with 10,000 simulations in a much reduced time. The results suggested that the number of simulations and the selection of parameters and models are important for the reliability of both the probability values and the sensitivity analyses.

Keywords: Biomechanics, Orthopedics, Finite element, Probability, Total hip replacement

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00036-8

doi:10.1016/j.medengphy.2009.01.002

Medical Engineering & Physics