Medical Engineering & Physics
Volume 31, Issue 6 , Pages 673-680, July 2009

The femur as a musculo-skeletal construct: A free boundary condition modelling approach

Department of Civil and Environment Engineering, Imperial College London, Structural Engineering Section, Skempton Building, London SW7 2AZ, UK

Received 6 October 2008; received in revised form 23 December 2008; accepted 31 December 2008. published online 09 February 2009.

Abstract 

Previous finite element studies of the femur have made simplifications to varying extents with regard to the boundary conditions used during analysis. Fixed boundary conditions are generally applied to the distal femur when examining the proximal behaviour at the hip joint, while the same can be said for the proximal femur when examining the distal behaviour at the knee joint. While fixed boundary condition analyses have been validated against in vitro experiments it remains a matter of debate as to whether the numerical and experimental models are indicative of the in vivo situation. This study presents a finite element model in which the femur is treated as a complete musculo-skeletal construct, spanning between the hip and knee joints. Linear and non-linear implementations of a free boundary condition modelling approach are applied to the bone through the explicit inclusion of muscles and ligaments spanning both the hip joint and the knee joint. A non-linear force regulated, muscle strain based activation strategy was found to result in lower observed principal strains in the cortex of the femur, compared to a linear activation strategy. The non-linear implementation of the model in particular, was found to produce hip and knee joint reaction forces consistent with in vivo data from instrumented implants.

Keywords: Femur, Finite element, Free boundary conditions, Muscles, Ligaments, Hip, Knee, Biomechanics, Structures

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(09)00034-4

doi:10.1016/j.medengphy.2008.12.008

Medical Engineering & Physics
Volume 31, Issue 6 , Pages 673-680, July 2009