Medical Engineering & Physics
Volume 31, Issue 5 , Pages 558-564 , June 2009

Automatic detection method of muscle fiber movement as revealed by ultrasound images

  • Tasuku Miyoshi

      Affiliations

    • Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-city, Saitama 3378570, Japan
    • Corresponding Author InformationCorresponding author at: Systems Engineering, Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-city, Saitama 3378570, Japan. Tel.: +81 48 6889405; fax: +81 48 6875197.
  • ,
  • Tomohiko Kihara

      Affiliations

    • Okayama University of Science, 1-1 Ridaicho, Okayama-city, Okayama 7000005, Japan
  • ,
  • Hiroyuki Koyama

      Affiliations

    • Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-city, Saitama 3378570, Japan
  • ,
  • Shin-Ichiro Yamamoto

      Affiliations

    • Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-city, Saitama 3378570, Japan
  • ,
  • Takashi Komeda

      Affiliations

    • Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-city, Saitama 3378570, Japan

Received 17 March 2008 ,Revised 7 November 2008 ,Accepted 14 November 2008.

References 

  1. Fukashiro S, Itoh M, Ichinose Y, Kawakami Y, Fukunaga T. Ultrasonography gives directly but noninvasively elastic characteristic of human tendon in vivo. European Journal of Applied Physiology and Occupational Physiology. 1995;71:555–557
  2. Fukunaga T, Ito M, Ichinose Y, Kuno S, Kawakami Y, Fukashiro S. Tendinous movement of a human muscle during voluntary contractions determined by real-time ultrasonography. Journal of Applied Physiology. 1996;81:1430–1433
  3. Fukunaga T, Kawakami Y, Kuno S, Funato K, Fukashiro S. Muscle architecture and function in humans. Journal of Biomechanics. 1997;30:457–463
  4. Muraoka T, Muramatsu T, Takeshita D, Kawakami Y, Fukunaga T. Length change of human gastrocnemius aponeurosis and tendon during passive joint motion. Cells Tissues and Organs. 2002;171:260–268
  5. Oda T, Himeno R, Hay DC, Chino K, Kurihara T, Nagayoshi T, et al. In vivo behavior of muscle fascicles and tendinous tissues in human tibialis anterior muscle during twitch contraction. Journal of Biomechanics. 2007;40:3114–3120
  6. Loram ID, Maganaris CN, Lakie M. Paradoxical muscle movement in human standing. Journal of Physiology. 2004;556:683–689
  7. Loram ID, Maganaris CN, Lakie M. Active, non-spring-like muscle movements in human postural sway: how might paradoxical changes in muscle length be produced?. Journal of Physiology. 2005;564:281–293
  8. Maganaris CN, Baltzopoulos V, Sargeant AJ. Human calf muscle responses during repeated isometric plantarflexions. Journal of Biomechanics. 2006;39:1249–1255
  9. Maganaris CN, Baltzopoulos V, Tsaopoulos D. Muscle fibre length-to-moment arm ratios in the human lower limb determined in vivo. Journal of Biomechanics. 2006;39:1663–1668
  10. Albracht K, Arampatzis A, Baltzopoulos V. Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo. Journal of Biomechanics. 2008;41:2211–2218
  11. Loram ID, Maganaris CN, Lakie M. Use of ultrasound to make noninvasive in vivo measurement of continuous changes in human muscle contractile length. Journal of Applied Physiology. 2006;100:1311–1323
  12. Fukui K. Edge extraction method based on separability of image features. IEICE Transactions on Information and Systems. 1995;E78-D:1533–1538
  13. Canny J. A computational approach to edge detection. IEEE Transactions on Pattern Analysis and Machine Intelligence. 1986;8:679–698
  14. Yakimovsky Y. Boundary and object detection in real world images. Journal of Association for Computing Machinery. 1976;23:599–618
  15. Otsu N. A threshold selection method from gray-level histograms. IEEE Transactions on Systems, Man and Cybernetics. 1979;9:62–66
  16. Herbert RD, Moseley AM, Butler JE, Gandevia SC. Change in length of relaxed muscle fascicles and tendons with knee and ankle movement in humans. Journal of Physiology. 2002;539:637–645

PII: S1350-4533(08)00208-7

doi: 10.1016/j.medengphy.2008.11.004

Medical Engineering & Physics
Volume 31, Issue 5 , Pages 558-564 , June 2009