Medical Engineering & Physics
Volume 31, Issue 4 , Pages 420-427, May 2009

Deformation simulation of cells seeded on a collagen-GAG scaffold in a flow perfusion bioreactor using a sequential 3D CFD-elastostatics model

  • C. Jungreuthmayer

      Affiliations

    • Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Ireland
    • Trinity Centre for Bioengineering, Department of Mechanical and Manufacturing Engineering, Trinity College Dublin, Dublin, Ireland
    • Siemens Medical Ireland, Leeson Close, Dublin 2, Ireland
  • ,
  • M.J. Jaasma

      Affiliations

    • Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Ireland
    • Trinity Centre for Bioengineering, Department of Mechanical and Manufacturing Engineering, Trinity College Dublin, Dublin, Ireland
  • ,
  • A.A. Al-Munajjed

      Affiliations

    • Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Ireland
    • Trinity Centre for Bioengineering, Department of Mechanical and Manufacturing Engineering, Trinity College Dublin, Dublin, Ireland
  • ,
  • J. Zanghellini

      Affiliations

    • Institute of Chemistry, Karl Franzens University Graz, Graz, Austria
  • ,
  • D.J. Kelly

      Affiliations

    • Trinity Centre for Bioengineering, Department of Mechanical and Manufacturing Engineering, Trinity College Dublin, Dublin, Ireland
  • ,
  • F.J. O’Brien

      Affiliations

    • Department of Anatomy, Royal College of Surgeons in Ireland, Dublin, Ireland
    • Trinity Centre for Bioengineering, Department of Mechanical and Manufacturing Engineering, Trinity College Dublin, Dublin, Ireland
    • Corresponding Author InformationCorresponding author at: Department of Anatomy, Royal College of Surgeons in Ireland, 123 St. Stephen's Green, Dublin 2, Ireland. Tel.: +353 1 402 2149; fax: +353 1 402 2355.

Received 14 December 2007; received in revised form 30 April 2008; accepted 11 November 2008. published online 25 December 2008.

Abstract 

Tissue-engineered bone shows promise in meeting the huge demand for bone grafts caused by up to 4 million bone replacement procedures per year, worldwide. State-of-the-art bone tissue engineering strategies use flow perfusion bioreactors to apply biophysical stimuli to cells seeded on scaffolds and to grow tissue suitable for implantation into the patient's body. The aim of this study was to quantify the deformation of cells seeded on a collagen-GAG scaffold which was perfused by culture medium inside a flow perfusion bioreactor. Using a μCT scan of an unseeded collagen-GAG scaffold, a sequential 3D CFD-deformation model was developed. The wall shear stress and the hydrostatic wall pressure acting on the cells were computed through the use of a CFD simulation and fed into a linear elastostatics model in order to calculate the deformation of the cells. The model used numerically seeded cells of two common morphologies where cells are either attached flatly on the scaffold wall or bridging two struts of the scaffold. Our study showed that the displacement of the cells is primarily determined by the cell morphology. Although cells of both attachment profiles were subjected to the same mechanical load, cells bridging two struts experienced a deformation up to 500 times higher than cells only attached to one strut. As the scaffold's pore size determines both the mechanical load and the type of attachment, the design of an optimal scaffold must take into account the interplay of these two features and requires a design process that optimizes both parameters at the same time.

Keywords: Collagen, Scaffold, Cell deformation, Fluid shear stress, Micro CT, Bioreactor, Computational fluid dynamics, Finite element analysis

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(08)00205-1

doi:10.1016/j.medengphy.2008.11.003

Medical Engineering & Physics
Volume 31, Issue 4 , Pages 420-427, May 2009