Medical Engineering & Physics
Volume 31, Issue 5 , Pages 522-527 , June 2009

Finger beat-to-beat blood pressure responses to successive hand elevations

Received 28 March 2008 ,Revised 21 July 2008 ,Accepted 5 October 2008.

References 

  1. Guelen I, Westerhof BE, van Der Sar GL, van Montfrans GA, Kiemeneij F, Wesseling KH, et al. Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Press Monit. 2003;8:27–30
  2. Schutte AE, Huisman HW, van Rooyen JM, Oosthuizen W, Jerling JC. Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function. Blood Press Monit. 2003;8:195–201
  3. Parati G, Ongaro G, Bilo G, Glavina F, Castiglioni P, Di Rienzo M, et al. Non-invasive beat-to-beat blood pressure monitoring: new developments. Blood Press Monit. 2003;8:31–36
  4. Peñáz J. Photoelectric measurement of blood pressure, volume and flow in the finger. In: Digest of the 10th International Conference on Medical and Biological Engineering. Dresden. 1973;p. 104
  5. Reeben V, Epler M. Indirect Continuous Measurement of Mean Arterial Pressure. In:  Ghista DN editors. Advances in cardiovascular physics, cardiovascular engineering. Part II. Monitoring. 5:Basel: Karger; 1983;p. 90–118
  6. Jones RDM, Kornberg JP, Roulson CJ, Visram AR, Irwin MG. The Finapres 2300e finger cuff. Anaesthesia. 1993;48:611–615
  7. Jagomägi K, Talts J, Raamat R, Länsimies E. Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method. Clin Physiol. 1996;16:551–560
  8. Smith NT, Wesseling KH, de Wit B. Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger. J Clin Monit. 1985;1:17–29
  9. Wesseling KH. Finapres, continuous noninvasive finger arterial pressure based on the method of Peñáz. In:  Rüddel H,  Curio I editor. Non-invasive continuous blood pressure measurement. Bern, New York, Paris: Peter Lang, Frankfurt am Main; 1991;p. 9–17
  10. Imholz BPM, Parati G, Mancia G, Wesseling KH. Effects of graded vasoconstriction upon the measurement of finger arterial pressure. J Hypertens. 1992;10:979–984
  11. Fortin J, Marte W, Grüllenberger R, Hacker A, Habenbacher W, Heller A, et al. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–957
  12. Peñáz J. Criteria for set point estimation in the volume clamp method of blood pressure measurement. Physiol Res. 1992;41:5–10
  13. Jepsen H, Gaehtgens P. Postural vascular response in human skin: passive and active reactions to alteration of transmural pressure. Am J Physiol Heart Circ Physiol. 1993;265:H949–H958
  14. Sun M, Jones R. A hydrostatic method assessing accuracy and reliability while revealing asymmetry in blood pressure measurements. Biomed Instrum Technol. 1995;29:331–342
  15. Gizdulich P, Aschero G, Guerrisi M, Wesseling KH. Effect of hydrostatic pressure on finger pressure measured non-invasively by Finapres. Homeostasis. 1995;36(2–3):120–129
  16. Raamat R, Talts J, Jagomägi K, Kivastik J, Länsimies E, Jurvelin J. Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change. J Med Eng Technol. 2006;30:139–144
  17. Ursino M, Cristalli C. A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement. IEEE Trans Biomed Eng. 1996;43:761–778
  18. Peñáz J, Honzikova N, Jurak P. Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries. Med Biol Eng Comput. 1997;35:633–637
  19. Wesseling KH, de Wit B, van der Hoeven GMA, van Goudoever J, Settels JJ. Physiocal, calibrating finger vascular physiology for Finapres. Homeostasis. 1995;36(2–3):67–82
  20. Bayliss WM. On the local reactions of the arterial wall to changes of internal pressure. J Physiol. 1902;28:220–231
  21. Jagomägi K, Raamat R, Talts J. Effect of altering vasoactivity on the measurement of finger blood pressure. Blood Press Monit. 2001;6:33–40
  22. Raamat R, Jagomägi K, Talts J. Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion. J Med Eng Technol. 2000;24:95–101
  23. Raamat R, Jagomägi K, Talts J, Länsimies E, Jurvelin J, Kolari P. Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling. Med Biol Eng Comput. 2001;39:584–589
  24. Raamat R, Jagomägi K, Talts J. Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance. Clin Physiol Funct Imaging. 2007;27(6):354–362
  25. Birch A. Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique. Blood Pres Monit. 2007;12:211–214
  26. Raamat R, Talts J, Jagomägi K. Application of amplitude-based and slope-based algorithms to determine beat-to-beat finger arterial compliance during handgrip exercise. Med Eng Phys. 2008;30:67–74
  27. Tschakovsky ME, Hughson RL. Venous emptying mediates a transient vasodilation in the human forearm. Am J Physiol Heart Circ Physiol. 2000;279:H1007–H1014
  28. Bergersen TK, Eriksen M, Walløe L. Local constriction of arteriovenous anastomoses in the cooled finger. Am J Physiol. 1997;273:R880–R886
  29. Tanaka H, Thulesius O. Effect of temperature on finger artery pressure evaluated by volume clamp technique. Clin Physiol. 1993;13:535–545
  30. Hiller B. The hydrostatic measurement of systolic toe blood pressure: a preliminary validation of the method. VASA. 1998;27:229–232
  31. Lopez-Beltran EA, Blackshear PL, Finkelstein SM, Cohn JN. Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method. Med Biol Eng Comput. 1998;36:748–753
  32. Shaltis P, Reisner A, Asada H. A hydrostatic pressure approach to cuffless blood pressure monitoring. Conf Proc IEEE Eng Med Biol Soc. 2004;3:2173–2176
  33. McCombie DB, Shaltis PA, Reisner AT, Asada HH. Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Lyon, France. 2007;p. 371–373

PII: S1350-4533(08)00177-X

doi: 10.1016/j.medengphy.2008.10.002

Medical Engineering & Physics
Volume 31, Issue 5 , Pages 522-527 , June 2009