« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 5
, Pages 522-527
, June 2009
Finger beat-to-beat blood pressure responses to successive hand elevations
References
- . Finometer, finger pressure measurements with the possibility to reconstruct brachial pressure. Blood Press Monit. 2003;8:27–30
- . Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function. Blood Press Monit. 2003;8:195–201
- . Non-invasive beat-to-beat blood pressure monitoring: new developments. Blood Press Monit. 2003;8:31–36
- . Photoelectric measurement of blood pressure, volume and flow in the finger. In: Digest of the 10th International Conference on Medical and Biological Engineering. Dresden. 1973;p. 104
- . Indirect Continuous Measurement of Mean Arterial Pressure. In: Ghista DN editors. Advances in cardiovascular physics, cardiovascular engineering. Part II. Monitoring. 5:Basel: Karger; 1983;p. 90–118
- . The Finapres 2300e finger cuff. Anaesthesia. 1993;48:611–615
- . Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method. Clin Physiol. 1996;16:551–560
- . Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger. J Clin Monit. 1985;1:17–29
- . Finapres, continuous noninvasive finger arterial pressure based on the method of Peñáz. In: Rüddel H, Curio I editor. Non-invasive continuous blood pressure measurement. Bern, New York, Paris: Peter Lang, Frankfurt am Main; 1991;p. 9–17
- . Effects of graded vasoconstriction upon the measurement of finger arterial pressure. J Hypertens. 1992;10:979–984
- . Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–957
- . Criteria for set point estimation in the volume clamp method of blood pressure measurement. Physiol Res. 1992;41:5–10
- . Postural vascular response in human skin: passive and active reactions to alteration of transmural pressure. Am J Physiol Heart Circ Physiol. 1993;265:H949–H958
- . A hydrostatic method assessing accuracy and reliability while revealing asymmetry in blood pressure measurements. Biomed Instrum Technol. 1995;29:331–342
- . Effect of hydrostatic pressure on finger pressure measured non-invasively by Finapres. Homeostasis. 1995;36(2–3):120–129
- . Simultaneous application of differential servo-oscillometry and volume-clamp plethysmography for continuous non-invasive recording of the finger blood pressure response to a hand postural change. J Med Eng Technol. 2006;30:139–144
- . A mathematical study of some biomechanical factors affecting the oscillometric blood pressure measurement. IEEE Trans Biomed Eng. 1996;43:761–778
- . Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries. Med Biol Eng Comput. 1997;35:633–637
- . Physiocal, calibrating finger vascular physiology for Finapres. Homeostasis. 1995;36(2–3):67–82
- . On the local reactions of the arterial wall to changes of internal pressure. J Physiol. 1902;28:220–231
- . Effect of altering vasoactivity on the measurement of finger blood pressure. Blood Press Monit. 2001;6:33–40
- . Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion. J Med Eng Technol. 2000;24:95–101
- . Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling. Med Biol Eng Comput. 2001;39:584–589
- . Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance. Clin Physiol Funct Imaging. 2007;27(6):354–362
- . Sympathetic peripheral vasoconstriction may be measured using an artifact of the Finapres volume clamp technique. Blood Pres Monit. 2007;12:211–214
- . Application of amplitude-based and slope-based algorithms to determine beat-to-beat finger arterial compliance during handgrip exercise. Med Eng Phys. 2008;30:67–74
- . Venous emptying mediates a transient vasodilation in the human forearm. Am J Physiol Heart Circ Physiol. 2000;279:H1007–H1014
- . Local constriction of arteriovenous anastomoses in the cooled finger. Am J Physiol. 1997;273:R880–R886
- . Effect of temperature on finger artery pressure evaluated by volume clamp technique. Clin Physiol. 1993;13:535–545
- . The hydrostatic measurement of systolic toe blood pressure: a preliminary validation of the method. VASA. 1998;27:229–232
- . Non-invasive studies of peripheral vascular compliance using a non-occluding photoplethysmographic method. Med Biol Eng Comput. 1998;36:748–753
- . A hydrostatic pressure approach to cuffless blood pressure monitoring. Conf Proc IEEE Eng Med Biol Soc. 2004;3:2173–2176
- . Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Lyon, France. 2007;p. 371–373
PII: S1350-4533(08)00177-X
doi: 10.1016/j.medengphy.2008.10.002
© 2008 IPEM. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 5
, Pages 522-527
, June 2009
