Medical Engineering & Physics
Volume 31, Issue 5 , Pages 533-538, June 2009

Evaluation of load transfer characteristics of a dynamic stabilization device on disc loading under compression

  • Qing Hang Zhang

      Affiliations

    • School of Mechanical and Aerospace Engineering, 50 Nanyang Ave, Nanyang Technological University, Singapore 639798, Singapore
  • ,
  • Yuan Li Zhou

      Affiliations

    • School of Mechanical and Aerospace Engineering, 50 Nanyang Ave, Nanyang Technological University, Singapore 639798, Singapore
  • ,
  • Dominique Petit

      Affiliations

    • FlexSpine Pte Ltd., Singapore
  • ,
  • Ee Chon Teo

      Affiliations

    • School of Mechanical and Aerospace Engineering, 50 Nanyang Ave, Nanyang Technological University, Singapore 639798, Singapore
    • Corresponding Author InformationCorresponding author. Tel.: +65 6790 5529.

Received 12 November 2007; received in revised form 19 September 2008; accepted 22 September 2008. published online 27 November 2008.

Abstract 

In the current study, finite element analyses were conducted to examine the biomechanical capability of a newly design dynamic stabilization system, FlexPLUS, to restore the load transmission of degenerated intervertebral L4-L5 lumbar motion segment spine under compression. Detailed three-dimensional FE models of L4-L5 motion segment and the FlexPLUS were developed. Compressive loading up to 1000N was applied to the intact L4-L5 model, the L4-L5 models with slight and moderate degenerated disc, and the implanted L4-L5 model. Further more, the load transmission characteristics of Dynesys and a rigid rod was also simulated for comparison. The resultant load–displacement curves and the load transferred through annulus under various conditions were compared. The predicted axial displacement of L4 top surface against applied compressive force of the intact L4-L5 model agreed well with experimental data. The predicted results showed that degenerated disc has significant effect on the lumbar segment load bearing capacity. Not only the stiffness of the segment was greatly increased, the uniform nature of the disc stress distribution was also altered. The FlexPLUS can effectively reduce the disc loading of degenerated model. Although the non-uniform load distribution pattern through annulus was not improved, the overall stress magnitude was greatly reduced to the level of intact model for grade II degeneration.

Keywords: Finite element, Dynamic stabilization, Compression, Degeneration, Lumbar spine

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(08)00176-8

doi:10.1016/j.medengphy.2008.09.011

Medical Engineering & Physics
Volume 31, Issue 5 , Pages 533-538, June 2009