« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 3
, Pages 314-319
, April 2009
Analysis of stresses in complete upper dentures with flat teeth at differing inclinations
References
- . Stress in denture base. Br Dent J. 1956;100:167–171
- . A functional stress analysis of the maxillary complete denture base. J Prosthet Dent. 1962;12:865–872
- . Investigation of strain produced in maxillary complete dentures. J Oral Reabil. 1979;6:241–256
- . Clinical studies of strain behaviour of complete dentures. J Biomed Eng. 1982;4:49–54
- . Clinical deformation of maxillary complete dentures. J Dent. 1983;11:224–230
- . Bite forces and frictional loading levels in maxillary complete dentures. Dent Mater. 1985;1:66–70
- . On the clinical deformation of maxillary complete dentures. Influence of the processing techniques of acrylate - based polymers. Acta Odontol Scand. 1988;46:287–295
- . On the clinical deformation of maxillary complete dentures. Influence of denture-base design and shape of denture-bearing tissue. Acta Odontol Scand. 1989;47:69–76
- . The functional deformation of maxillary complete dentures in patients with flabby alveolar ridges. Part II: after surgery. Swed Dent J. 1991;15:63–70
- . Three dimensional photoelastic stress analysis of maxillary complete denture. J Prosthet Dent. 1974;31:122–129
- . Using holography for the measurement of in vivo deformation in a complete maxillary denture. J Prosthet Dent. 1985;54:843–846
- . Finite element analysis of the stress concetrating effect of fraenal notches in complete dentures. Int J Prosthodont. 1990;3:238–240
- . Fracture surface characteristics of damaged acrylic-resin-based dentures as analysed by SEM-replica technique. J Oral Rehabil. 1996;23:524–529
- . Effects of the position of artificial teeth and load levels on the stress in the complete.maxillary denture. J Prosthet Dent. 2002;88:415–422
- . Comparison of the midline stress fields in maxillary and mandibular complete dentures: a pilot study. J Prosthet Dent. 2006;95:63–70
- . An analysis of cause of fracture of acrylic resin dentures. J Prosthet Dent. 1981;46:238–241
- . Complete denture base deformation with varied occlusal tooth form. J Prosthet Dent. 1956;6:714–718
- . The comminuting efficiency of varied occlusal tooth form and the associated deformation of the complete denture base. JADA. 1960;69:465–471
- . The effect of cusp form and the occlusal surface area on the denture base deformation. J Prosthet Dent. 1966;16:34–43
- . A unified multiaxial fatigue damage model for isotropic and anisotropic materials. Int J Fatigue. 2007;29:347–359
- . A multiaxial fatigue criterion for various metallic materials under proportional and nonproportional loading. Int J Fatigue. 2006;28:401–408
- . Lifetime simulation under multiaxial random loading with regard to the microcrack growth. Int J Fatigue. 2006;28:954–962
- . Fatigue of reinforced-polyurethane-based, sheet metal forming dies. Int J Fatigue. 2006;28:43–52
- . The mean stress effect on the high-cycle fatigue strength from a multiaxial fatigue point of view. Int J Fatigue. 2005;27:928–943
- . Anatomic versus nonanatomic teeth. J Prosthet Dent. 1953;3:747–754
- . Biomechanics and artificial posterior teeth. J Prosthet Dent. 1954;4:782–802
- . The occlusion and occlusal patterns of artificial posterior teeth. J Prosthet Dent. 1954;4:461–480
- . Factors affecting the masticatory performance of complete denture wearers. J Prosthet Dent. 1975;33:122–136
- . Bouchers's prosthetic treatment for edentoulous patients. 11th ed.. St. Louis: Mosby; 1997;p. 332–46
- . Experimental stress analysis. 2nd ed.. New York: Me Graw Hill Co.; 1978;p. 127–272
PII: S1350-4533(08)00109-4
doi: 10.1016/j.medengphy.2008.06.008
© 2008 IPEM. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Engineering & Physics
Volume 31, Issue 3
, Pages 314-319
, April 2009