Medical Engineering & Physics
Volume 31, Issue 3 , Pages 328-336 , April 2009

Study of tracheal collapsibility, compliance and stress by considering its asymmetric geometry

  • Zhongzhao Teng

      Affiliations

    • Department of Mathematical Sciences, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609, USA
    • Corresponding Author InformationCorresponding author. Tel.: +1 508 831 6725.
  • ,
  • Ignacio Ochoa

      Affiliations

    • Aragon Institute of Engineering Research (I3A), University of Zaragoza, Spain
  • ,
  • Zhiyong Li

      Affiliations

    • Department of Radiology, University of Cambridge, Cambridge, UK
  • ,
  • Manuel Doblare

      Affiliations

    • Aragon Institute of Engineering Research (I3A), University of Zaragoza, Spain

Received 27 September 2007 ,Revised 29 May 2008 ,Accepted 5 June 2008.

References 

  1. Penn RB, Wolfson MR, Shaffer TH. Influence of smooth muscle tone and longitudinal tension on the collapsibility of immature airways. Pediatric Pulmonology. 1988;5:132–138
  2. Deoras KS, Wolfson MR, Searls RL, Hilfer SR, Shaffer TH. Developmental changes in tracheal structures. Pediatric Research. 1991;30:170–175
  3. Teng ZZ, Liu ZR, Wang YQ, Tang WC, Liu BY. pV relationship and limit flow for collapsible trachea. Chinese Quarterly Mechanics. 2001;22(1):40–46
  4. Costantino ML, Fiore GB. A model of neonatal tidal liquid ventilation mechanics. Medical Engineering & Physics. 2001;23:457–471
  5. Fung YC. Biomechanics: motion, flow, stress, and growth. New York: Springer-Verlag; 1990;
  6. Teng ZZ, Ji GY, Chu HJ, Li ZY, Zou LJ, Xu ZY, et al. Does PGA external stenting reduce compliance mismatch in venous grafts?. Biomedical Engineering Online. 2007;6(12):
  7. Tang DL, Yang C, Zheng J, Woodard PK, Saffitz JE, Petruccelli JD, et al. Local maximal stress hypothesis and computational plaque vulnerability index for atherosclerotic plaque assessment. Annals of Biomedical Engineering. 2005;33(12):1789–1801
  8. Li ZY, Howarth S, Trivedi RA, UK-I J, Graves MJ, Brown A, et al. Stress analysis of carotid plaque rupture based on in vivo high resolution MRI. Journal of Biomechanics. 2006;39:2611–2622
  9. Lambert RK, Baile EM, Moreno RH, Bert J, Pare PD. A method for estimating the Young's modulus of complete tracheal cartilage rings. Journal of Applied Physiology. 1991;70:1152–1159
  10. Teng Z, Ochoa I, Li Z, Lin Y, Rodriguez JF, Bea JA, et al. Nonlinear mechanical property of tracheal cartilage: a theoretical and experimental study. Journal of Biomechanics. 2008;41:1995–2002
  11. Costantino ML, Bagnoli P, Dini G, Fiore GB, Soncini M, Corno C, et al. A numerical and experimental study of compliance and collapsibility of preterm lamb tracheae. Journal of Biomechanics. 2004;37:1837–1847
  12. Holzhauser U, Lambert RK. Analysis of tracheal mechanics and applications. Journal of Applied Physiology. 2001;91:290–297
  13. Wang YQ, Lin YH, Teng ZZ. A thin shell modeling for collapsible trachea. Journal of Fudan University (Natural Science). 2006;45:141–150
  14. Begis D, Delpuech CL, Tallec P, Loth L, Thiriet M, Vidrascu M. A finite-element model of tracheal collapse. Journal of Applied Physiology. 1988;64:1359–1368
  15. Rains JK, Bert JL, Roberts CR, Pare PD. Mechanical properties of human tracheal cartilage. Journal of Applied Physiology. 1992;72:219–225
  16. Ogden RW. Non-linear elastic deformations. New York: Wiley; 1984;
  17. Han HC, Fung YC. Residual strains in porcine and canine trachea. Journal of Biomechanics. 1991;24:307–315
  18. Teng ZZ, Liu ZR, Lin YH, Wang YQ, Li FF, Gong KQ. Study on cartilaginous and muscular strain of rat trachea. Science in China (Series C). 2004;47:485–493
  19. Roberts CR, Rains JK, Pare PD, Walker DC, Wiggs B, Bert JL. Ultrastructure and tensile properties of human tracheal cartilage. Journal of Biomechanics. 1998;31:81–86

PII: S1350-4533(08)00106-9

doi: 10.1016/j.medengphy.2008.06.006

Medical Engineering & Physics
Volume 31, Issue 3 , Pages 328-336 , April 2009