Medical Engineering & Physics
Volume 31, Issue 3 , Pages 337-345 , April 2009

Pulse onset detection using neighbor pulse-based signal enhancement

  • Peng Xu

      Affiliations

    • Neural Systems and Dynamics Laboratory, Department of Neurosurgery, The David Geffen School of Medicine, University of California, Los Angeles, United States
    • Center of Neuroinformatics, School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu 610054, China
  • ,
  • Marvin Bergsneider

      Affiliations

    • Neural Systems and Dynamics Laboratory, Department of Neurosurgery, The David Geffen School of Medicine, University of California, Los Angeles, United States
    • Biomedical Engineering Graduate Program, Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, United States
  • ,
  • Xiao Hu

      Affiliations

    • Neural Systems and Dynamics Laboratory, Department of Neurosurgery, The David Geffen School of Medicine, University of California, Los Angeles, United States
    • Biomedical Engineering Graduate Program, Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, United States
    • Corresponding Author InformationCorresponding author at: 100 Medical Plaza, Suite 219, Los Angeles, CA 90095, United States. Tel.: +1 310 825 9207; fax: +1 310 206 5234.

Received 6 February 2008 ,Revised 25 May 2008 ,Accepted 1 June 2008.

References 

  1. Zong W, Heldt T, Moody GB, Mark RG. An open-source algorithm to detect onset of arterial blood pressure pulses. Comput Cardiol. 2003;30:259–262
  2. McDonald DA. Regional pulse-wave velocity in the arterial tree. J Appl Physiol. 1968;24:73–78
  3. Chiu YC, Arand PW, Shroff SG, Feldman T, Carroll JD. Determination of pulse wave velocities with computerized algorithms. Am Heart J. 1991;121:1460–1470
  4. Kim CH, Park JH, Park TS, Baek HS. Correlation between coronary artery disease and aortic-pulse wave velocity in patients with type 2 diabetes. Diabetes. 2004;53:A180–A1180
  5. Jago JR, Murray A. Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. Clinical Phys Physiol Meas. 1988;9:319–329
  6. Sutton-Tyrrell K, Najjar SS, Boudreau RM, Venkitachalam L, Kupelian V, Simonsick EM, et al. Elevated aortic pulse wave velocity, a marker of arterial stiffness, predicts cardiovascular events in well-functioning older adults. Circulation. 2005;111(25):3384–3390
  7. Mitchell GF, Pfeffer MA, Finn PV, Pfeffer JM. Comparison of techniques for measuring pulse-wave velocity in the rat. J Appl Physiol. 1997;82:203–210
  8. Egidijus KRG, Arunas V. Mathematical methods for determining the foot point of the arterial pulse wave and evaluation of proposed methods. Inform Technol control. 2005;34:29–36
  9. Isnard RN, Pannier BM, Laurent S, London GM, Diebold B, Safar ME. Pulsatile diameter and elastic modulus of the aortic arch in essential hyper-tension: a noninvasive study. J Am Coll Cardiol. 1989;13:399–405
  10. Aboy M, McNames J, Thong T, Tsunami D, Ellenby MS, Goldstein B. An automatic beat detection algorithm for pressure signals. IEEE Trans Biomed Eng. 2005;52(10):1662–1670
  11. Nichols WW, O’Rourke MF. In: McDonald's Blood Flow in Arteries. 5th edition. Oxford University press Inc.; 2005;
  12. Smith L. A tutorial on Principal Component Analysis, 2002.
  13. Rao CR. The use and interpretation of principal component analysis in applied research. Sankhya A. 1964;26:329–358
  14. Hu X, Xu P, Lee D, Vespa P, Bergsneider M. An algorithm of extracting intracranial pressure latency relative to electrocardiogram R wave. Physiol Meas. 2008;29:459–471
  15. Schlögl A, Müller GR, Scherer R, Pfurtscheller G. BIOSIG—An Open Source Software Package for biomedical Signal Processing. 2nd OpenECG Workshop, 2004:13.
  16. Kohler BU, Hennig C, Orglmeister R. The principles of software QRS detection. IEEE Eng Med Biol Mag. 2002;21:42–57
  17. Nitzan M, Khanokh B, Slovik Y. The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol Meas. 2002;23:85–93
  18. Hu X, Nenov V. A single-lead ECG enhancement algorithm using a regularized data-driven filter. IEEE Trans Biomed Eng. 2006;53:347–351
  19. Kotas M. Projective filtering of time-aligned ECG beats. IEEE Trans Biomed Eng. 2004;51:1129–1139
  20. Olmos S, Garcia J, Jane R, Laguna P. Truncated orthogonal expansions of recurrent signals: equivalence to a linear time-variant periodic filter. IEEE Trans Signal Process. 1999;47(11):3164–3172
  21. Richter M, Schreiber T, Kaplan DT. Fetal ECG extraction with nonlinear state-space projections. IEEE Trans Biomed Eng. 1998;45:133–137

PII: S1350-4533(08)00102-1

doi: 10.1016/j.medengphy.2008.06.005

Medical Engineering & Physics
Volume 31, Issue 3 , Pages 337-345 , April 2009