Medical Engineering & Physics
Volume 30, Issue 6 , Pages 717-724, July 2008

Orthogonal cutting of cancellous bone with application to the harvesting of bone autograft

Bioengineering Institute, Level 6, 70 Symonds Street, Auckland, New Zealand

Received 28 April 2006; received in revised form 22 February 2007; accepted 28 February 2007. published online 07 September 2007.

Abstract 

Autogenous bone graft harvesting results in cell death within the graft and trauma at the donor site. The latter can be mitigated by using minimally invasive tools and techniques, while cell morbidity may be reduced by improving cutter design and cutting parameters. We have performed orthogonal cutting experiments on bovine cancellous bone samples, to gain a basic understanding of the cutting mechanism and to determine design guidelines for tooling. Measurements were performed at cutting speeds from 11.2 to 5000mm/min, with tool rake angles of 23, 45 and 60, and depths of cut in the range of 0.1–3.0mm. Horizontal and vertical cutting forces were measured, and the chip formation process video recorded. Continuous chip formation was observed for rake angles of 45 and 60, and depths of cut greater than 0.8mm. Chip formation for depths of cut greater than 1.0mm was accompanied by bone marrow extruding out of the free surfaces and away from the rake face. Specific cutting energies decreased with increasing rake angle, increasing depth of cut and increasing cutting speed. Our orthogonal cutting experiments showed that a rake angle of 60 and a depth of cut of 1mm, will avoid excessive fragmentation, keep specific cutting energy low and promote bone marrow extrusion, which may be beneficial for cell survival. We demonstrate how drill bit clearance angle and feed rate can be calculated facilitating a 1mm depth of cut.

Keywords: Orthogonal cutting, Cancellous bone, Bone graft tooling, Bone autograft, Chip formation, Cutting forces, Specific cutting energy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00149-X

doi:10.1016/j.medengphy.2007.02.010

Medical Engineering & Physics
Volume 30, Issue 6 , Pages 717-724, July 2008