Simulation of high tensile Poisson's ratios of articular cartilage with a finite element fibril-reinforced hyperelastic model

Escuela de Ingeniería Civil y Geomática, Universidad del Valle, Calle 13, Carrera 100, Edificio 350, Cali, Colombia

Received 7 February 2007; received in revised form 26 June 2007; accepted 27 June 2007. published online 10 August 2007.

Abstract 

Analyses with a finite element fibril-reinforced hyperelastic model were undertaken in this study to simulate high tensile Poisson's ratios that have been consistently documented in experimental studies of articular cartilage. The solid phase was represented by an isotropic matrix reinforced with four sets of fibrils, two of them aligned in orthogonal directions and two oblique fibrils in a symmetric configuration respect to the orthogonal axes. Two distinct hyperelastic functions were used to represent the matrix and the fibrils. Results of the analyses showed that only by considering non-orthogonal fibrils was it possible to represent Poisson's ratios higher than one. Constrains in the grips and finite deformations played a minor role in the calculated Poisson's ratio. This study also showed that the model with oblique fibrils at 45° was able to represent significant differences in Poisson's ratios near 1 documented in experimental studies. However, even considering constrains in the grips, this model was not capable to simulate Poisson's ratios near 2 that have been reported in other studies. The study also confirmed that only with a high relation between the stiffness of the fibers and that of the matrix was it possible to obtain high Poisson's ratios for the tissue. Results suggest that analytical models with a finite number of fibrils are appropriate to represent main mechanical effects of articular cartilage.

Keywords: Anisotropy of cartilage, Tensile Poisson's ratio, Hyperelastic fibril-reinforced models

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00134-8

doi:10.1016/j.medengphy.2007.06.004

Medical Engineering & Physics
Volume 30, Issue 5 , Pages 590-598, June 2008