Power output and metabolic cost of synchronous and asynchronous submaximal and peak level hand cycling on a motor driven treadmill in able-bodied male subjects

  • Lucas H.V. van der Woude

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands
    • Rehabilitation Center Amsterdam, The Netherlands
    • Corresponding Author InformationCorresponding author at: Faculty of Human Movement Sciences, Research Institute MOVE, VU University, Van der Boechorststraat 9, 1081 BT Amsterdam, The Netherlands. Tel.: +31 20 5988500; fax: +31 20 5988529.
  • ,
  • Astrid Horstman

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands
  • ,
  • Paul Faas

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands
  • ,
  • Sander Mechielsen

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands
  • ,
  • Hamid Abbasi Bafghi

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands
  • ,
  • Jos J. de Koning

      Affiliations

    • Faculty of Human Movement Sciences, Research Institute MOVE, Institute for Fundamental and Clinical Human Movement Sciences, VU University, Amsterdam, The Netherlands

Received 6 December 2006; received in revised form 25 May 2007; accepted 16 June 2007. published online 20 August 2007.

Abstract 

Purpose

To evaluate external power output and physiological responses of synchronous (SYNC) and asynchronous hand cycling (ASYNC) at submaximal and peak levels of exercise.

Methods

n=9 able-bodied male subjects (age: 20.1±2.1 years) performed two (sub)maximal continuous hand cycle exercise tests, using the SYNC and ASYNC mode in a standardized commercial add-on hand cycle unit (counter-balanced order). Treadmill speed (1.89 and 2.17ms−1) and slope (steps of +1%) were changed in a fixed sequence of 3-min exercise steps. Gears were adjusted to 65rpm. External power output (PO) was continuously monitored with a strain-gauge instrumented chain ring ((SRM) Schoberer Rad Messtechnik). A conventional wheelchair drag test was performed to validate mean external power for each speed-slope combination. Heart rate (HR; bpm) and oxygen uptake (VO2; mlkg−1min−1, SMTP) were continuously monitored. Paired T-tests and ANOVA for repeated measures evaluated effects of mode and exercise level (p<0.05).

Results

Subjects reached peak levels of performance (RER: 1.05±0.07 versus 1.10±0.1 for SYNC and ASYNC). Peak PO and were significantly higher for SYNC (81.6±11.8W versus 68.5±10.6W; 26.4±4.5mlkg−1min−1 versus 21.2±3.0mlkg−1min−1).

At submaximal exercise levels, gross mechanical efficiency (ME) was significantly higher for SYNC (12.1±0.9% versus 9.7±1.4% at 41W). No significant differences were found for PO (at equal velocity and slope), as derived from the SRM (SYNC and ASYNC), and from the drag test.

Discussion

The absence of any differences in PO between SYNC and ASYNC, and with respect to the drag test, rules out ‘additional external work due to maintain the desired heading’ in the ASYNC as an explanation for the lower performance in this mode. Lower peak performance and ME in ASYNC may be explained by the increased stabilizing muscle effort in the upper extremities and trunk in order to combine power production with stable steering. ASYNC is less efficient compared to SYNC. Similarly, peak performance capacity was higher for SYNC.

Conclusion

External work does not differ between SYNC and ASYNC hand cycling. SRM readings appear valid for PO monitoring in hand cycling within the studied range of PO. SYNC is more efficient than ASYNC and leads to higher peak performance.

Keywords: Hand cycle, Hand bike, (Sub)maximal exercise, Able-bodied, Cardio-respiratory strain, Mechanical efficiency, Power output

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00132-4

doi:10.1016/j.medengphy.2007.06.006

Medical Engineering & Physics
Volume 30, Issue 5 , Pages 574-580, June 2008