« Previous
Next »
Medical Engineering & Physics
Volume 30, Issue 6
, Pages 680-686
, July 2008
MicroPET reconstruction with random coincidence correction via a joint Poisson model
References
- Evaluation of 3D reconstruction algorithms for a small animal PET camera. IEEE Trans Nucl Sci. 1997;44:1303–1308
- Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET. IEEE Trans Med Imag. 2000;19:507–512
- . Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imag. 1982;MI-1:113–122
- . EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr. 1984;8:306–316
- . A statistical model for positron emission tomography. J Am Stat Assoc. 1985;80:8–20
- . Parallelization of the EM algorithm for 3D PET image reconstruction. IEEE Trans Med Imag. 1991;10:513–522
- . Quantization in positron emission computed tomography: 4. Effect of accidental coincidences. J Comput Assist Tomogr. 1981;5:391–400
- . Quantization in positron emission computed tomography: 7 a technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration. J Comput Assist Tomogr. 1986;10:845–850
- . Random correction for positron emission tomography using singles count rates. IEEE Nucl Sci Symp Conf Rec. 2000;3:1737–1740
- . Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography. IEEE Trans Med Imag. 1991;10:82–89
- . On complete-data spaces for PET reconstruction algorithms. IEEE Trans Nucl Sci. 1993;40:1055–1061
- . On accelerated cross-reference maximum likelihood estimates for positron emission tomography. In: Conference Record of 1997 IEEE Nuclear Science Symposium, vol. 2. 1997;p. 1484–1488
- . Cross-reference weighted least square estimates for positron emission tomography. IEEE Trans Med Imag. 1998;17:1–8
- . Iterative image reconstruction with random correction for PET studies. In: Proceedings of the Society of Photo-Optical Instrumentation Engineers, vol. 3979. 2000;p. 1218–1229
- . Correction methods for random coincidences in 3D whole body PET imaging. In: IEEE Nuclear Science Symposium and Medical Imaging Conference, vol. 4. San Diego, CA. 2001;p. 2080–2084
- . New statistical models for random pre-corrected PET scans. In: Duncan J, Gindi G editor. Information processing in medical imaging (lecture notes in computer science). vol. 1230:Springer–Verlag; 1997;p. 190–203
- . Exact and approximate rebinning algorithms for 3-D PET data. IEEE Trans Med Imag. 1997;16:145–158
PII: S1350-4533(07)00101-4
doi: 10.1016/j.medengphy.2007.05.013
© 2007 IPEM. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Engineering & Physics
Volume 30, Issue 6
, Pages 680-686
, July 2008
