Automatic detection of ultrasonic Doppler signal episodes resulting from fetal breathing movements

  • K. Kałużyński

      Affiliations

    • Institute for Precision and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland
    • Corresponding Author InformationCorresponding author.
  • ,
  • T. Kret

      Affiliations

    • Institute for Precision and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland
  • ,
  • J. Sieńko

      Affiliations

    • 2nd Department of Obstetrics and Gynecology, Medical University of Warsaw, Poland
  • ,
  • K. Czajkowski

      Affiliations

    • 2nd Department of Obstetrics and Gynecology, Medical University of Warsaw, Poland
  • ,
  • T. Pałko

      Affiliations

    • Institute for Precision and Biomedical Engineering, Warsaw University of Technology, Warsaw, Poland

Received 31 January 2007; received in revised form 23 April 2007; accepted 27 April 2007. published online 19 June 2007.

Abstract 

A method for automatic detection of fetal breathing movements has been proposed, based on the time-frequency structure of the corresponding continuous wave ultrasonic Doppler signals. The method uses spectral analysis of the envelope of the directional Doppler signal and cross-correlation analysis of both directional envelopes. Detection rule comprises the following criteria: presence of the peak in the envelope spectrum and of the adequate signal level in the frequency range corresponding to the fetal breathing rhythm, the peak value and the position limits of the peak of the cross-correlation coefficient of the both directional envelopes. The effect of the criteria setting on the rule performance and the tradeoff between the specificity and sensitivity was investigated. The rule is most sensitive to the threshold value of the cross-correlation coefficient of the envelopes. The limits of the position of this peak are crucial for the distinction between the breathing episodes and hiccups. The optimal settings of the criteria, resulting in average sensitivity and specificity exceeding, respectively, 0.70 and 0.80, are proposed.

Keywords: Doppler ultrasound, Spectral analysis, Correlation, Wavelet transform, Fetal breathing, Fetal well-being, Decision rule

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00090-2

doi:10.1016/j.medengphy.2007.04.015

Medical Engineering & Physics
Volume 30, Issue 4 , Pages 426-433, May 2008