Medical Engineering & Physics
Volume 30, Issue 2 , Pages 190-198, March 2008

Clinical validation of three-dimensional tortuosity metrics based on the minimum curvature of approximating polynomial splines

  • Geoff Dougherty

      Affiliations

    • Applied Physics, California State University Channel Islands, Camarillo, CA 93012, USA
    • Corresponding Author InformationCorresponding author. Tel.: +1 805 437 8990; fax: +1 805 437 2765.
  • ,
  • Michael J. Johnson

      Affiliations

    • Department of Mathematics and Computer Science, Kuwait University, P.O. Box 5969, Safat 13060, Kuwait

Received 5 August 2006; received in revised form 22 February 2007; accepted 24 February 2007. published online 11 April 2007.

Abstract 

The clinical recognition of abnormal vascular tortuosity is important in the diagnosis of many diseases. Metrics based on three-dimensional (3D) curvature, using approximating polynomial spline-fitting to “data balls” centered along the mid-line of the vessel, minimize digitization errors and give tortuosity values largely independent of the resolution of the imaging system. We applied two of these metrics to a number of clinical vascular systems, using both 2D and 3D datasets. Using abdominal aortograms of low tortuosity, we established their validity by their strong correlation with the ranking of an expert panel of three vascular surgeons. The values of the Spearman rank correlation coefficient between our rankings, using a data ball radius of one-quarter of the local vessel radius, and the average ranking of the expert panel were 0.96 (with a 95% confidence interval of [0.91, 0.99]) for the mean curvature and 0.98 ([0.94, 0.99]) for the root-mean-square (RMS) curvature. These confidence intervals indicate that our automated analysis is producing rankings whose reliability is similar to that of a human expert, and is significantly better than that achieved with existing algorithms. The metrics provided good discrimination between vessels of different tortuosity for both 2D and 3D datasets, and produced values sufficiently discriminating to assess the relative utility of arteries for endoluminal repair of aneurysms.

Keywords: Tortuosity, Blood vessels, MRA, Endoluminal repair

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00041-0

doi:10.1016/j.medengphy.2007.02.009

Medical Engineering & Physics
Volume 30, Issue 2 , Pages 190-198, March 2008