Medical Engineering & Physics
Volume 30, Issue 1 , Pages 1-8, January 2008

2D modeling and preliminary in vitro investigation of a prototype high gradient magnetic separator for biomedical applications

  • Haitao Chen

      Affiliations

    • Department of Neurology, The University of Chicago Pritzker School of Medicine, Chicago, IL 60637, USA
    • Department of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL 60616, USA
  • ,
  • Michael D. Kaminski

      Affiliations

    • Chemical Engineering Division, Argonne National Laboratory, Argonne, IL 60439, USA
  • ,
  • Axel J. Rosengart

      Affiliations

    • Department of Neurology, The University of Chicago Pritzker School of Medicine, Chicago, IL 60637, USA
    • Department of Surgery (Neurosurgery), The University of Chicago Pritzker School of Medicine, Chicago, IL 60637, USA
    • Corresponding Author InformationCorresponding author at: The University of Chicago Pritzker School of Medicine, 5841 South Maryland Avenue, MC 2030, Chicago, IL 60637, USA. Tel.: +1 773 702 2364; fax: +1 773 834 4612.

Received 11 August 2006; received in revised form 25 January 2007; accepted 4 February 2007. published online 02 April 2007.

Abstract 

High gradient magnetic separation (HGMS) of magnetic materials from fluids or waste products has many established industrial applications. However, there is currently no technology employing HGMS for ex-vivo biomedical applications, such as for the removal of magnetic drug- or toxin-loaded spheres from the human blood stream. Importantly, human HGMS applications require special design modifications as, in contrast to conventional use where magnetic elements are permanently imbedded within the separation chambers, medical separators need to avoid direct contact between the magnetic materials and blood to reduce the risk of blood clotting and to facilitate convenient and safe treatment access for many individuals.

We describe and investigate the performance of a magnetic separator prototype designed for biomedical applications. First, the capture efficiency of a prototype HGMS separator unit consisting of a short tubing segment and two opposing magnetizable fine wires along the outside of the tubing was investigated using 2D mathematical modeling. Second, the first-pass effectiveness to remove commercially available, magnetic polystyrene spheres from human blood using a single separator unit was experimentally verified. The theoretical and experimental data correlated well at low flow velocities (<5.0cm/s) and high external magnetic fields (>0.05T). This prototype separator unit removed >90% in a single pass of the magnetic spheres from water at mean flow velocity ≤8.0cm/s and from blood mimic fluids (ethylene glycol–water solutions) at mean flow velocity ≤2.0cm/s. In summary, we describe and prove the feasibility of a HGMS separator for biomedical applications.

Keywords: Magnetic separator, Magnetic spheres, High gradient magnetic separation, Blood detoxification, Simulation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(07)00034-3

doi:10.1016/j.medengphy.2007.02.002

Medical Engineering & Physics
Volume 30, Issue 1 , Pages 1-8, January 2008