Medical Engineering & Physics
Volume 30, Issue 1 , Pages 20-33, January 2008

A new approach to characterize grip force applied to a cylindrical handle

Engineering & Control Technology Branch, National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, MS L-2027, WV 26505, USA

Received 21 July 2006; received in revised form 16 January 2007; accepted 20 January 2007. published online 09 March 2007.

Abstract 

The grip force applied to a cylindrical handle is a function of the measurement reference axis. So far, however, no attempt has been made to fully describe the exact form of this function. The objectives of this study were to examine some fundamental characteristics of grip forces and to explore the basic pattern of the grip force function. Twenty subjects (10 males and 10 females) participated in the experiment. The subjects alternately used their left and right hands to apply maximum grip forces and medium grip forces (about 40% of maximum) to a 30mm handle. A flexible pressure sensor mat was used to measure the grip pressure. The pressure was integrated with respect to different measurement axes; this resulted in the grip force function. This study found that every gripping action produces maximum and minimum force axes; these axes are separated by about 90°. The maximum force is correlated with the minimum force, but the former is generally about 1.42 times the latter. The principal grip direction is about 78° from the zh-axis of the hand biodynamic coordinate system defined in ISO 8727 [ISO 8727. Mechanical vibration and shock – human exposure – biodynamic coordinate systems. Geneva, Switzerland: International Organization for Standardization; 1997]. More interestingly, each of the 160 sets of experimental data reasonably fit this study's proposed elliptical model. The implications of the findings are discussed.

Keywords: Grip force, Grip strength, Hand force, Hand, Grip pressure

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health.

PII: S1350-4533(07)00031-8

doi:10.1016/j.medengphy.2007.01.002

Medical Engineering & Physics
Volume 30, Issue 1 , Pages 20-33, January 2008