Medical Engineering & Physics
Volume 29, Issue 10 , Pages 1142-1148 , December 2007

Simulated parametric studies in optical imaging of tumors through temporal log-slope difference mapping

Received 30 March 2006 ,Revised 7 December 2006 ,Accepted 9 December 2006.

References 

  1. Ntziachristos V, Yodh AG, Schnall M, Chance B. Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement. PNAS. 2000;97:2767–2772
  2. Hebden JC, Veenstra H, Dehghani H, Hillman EMC, Schweiger M, Arridge SR, et al. Three dimensional time-resolved optical tomography of a conical breast phantom. Appl Opt. 2001;40:3278–3287
  3. Roy R, Godavarty A, Sevick-Muraca EM. Fluorescence-enhanced optical tomography using referenced measurements of heterogeneous media. IEEE Trans Med Imaging. 2003;22:824–836
  4. Benaron DA, Hintz SR, Villringer A, Boas D, Kleinschmidt A, Frahm J, et al. Noninvasive functional imaging of human brain using light. J Cereb Blood Flow Metab. 2000;20:469–477
  5. Arridge SR. Optical tomography in medical imaging. Inverse Probl. 1999;15:41–93
  6. Boas DA, Strangman G, Culver JP, Hoge RD, Jasdzewski G, Poldrack RA, et al. Can the cerebral metabolic rate of oxygen be estimated with near infrared spectroscopy?. Phys Med Biol. 2003;48:2405–2418
  7. Weissleder R, Tung CH, Mahmood U, Bogdanov A. In vivo imaging of tumor with protease-activated near-infrared fluorescent probes. Nat Biotechnol. 1999;17:375–378
  8. Guo Z, Wan SK, Kim KH, Kosaruja C. Comparing diffusion approximation with radiation transfer analysis for light transport in tissues. Opt Rev. 2003;10:415–421
  9. Guo Z, Kim KH. Ultrafast laser radiation transfer in heterogeneous tissues using discrete ordinates method. Appl Opt. 2003;42:2897–2905
  10. Wan SK, Guo Z, Kumar S, Aber J, Garetz BA. Noninvasive detection of inhomogeneity in turbid media time-resolved log-slop analysis. JQSRT. 2004;84:493–500
  11. Guo Z, Wan SK, August DA, Ying JP, Dunn SM, Semmlow JL. Optical imaging of breast tumor through temporal log-slope difference mappings. Comp Bio Med. 2006;36:209–223
  12. Chance B, Nioka S, Kent J, McCully K, Fountain M, Greenfeld R, et al. Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. Anal Biochem. 1988;174:698–707
  13. Patterson MS, Chance B, Wilson BC. Time-resolved reflectance and transmittance for the noninvasive measurement of tissue optical properties. Appl Opt. 1989;28:2331–2336
  14. Liu F, Yoo YM, Alfano RR. Ultrafast laser-pulse transmission and imaging through biological tissues. Appl Opt. 1993;32:554–558
  15. Wu J, Perelman L, Dasari RR, Feld MS. Fluorescence tomographic imaging in turbid media using early-arriving photons and Laplace transforms. PNAS. 1997;94:8783–8788
  16. Guo Z, Aber J, Garetz B, Kumar S. Monte Carlo simulation and experiments of pulsed radiative transfer. JQSRT. 2002;73:159–168
  17. Zysk AM, Chaney EJ, Boppart SA. Refractive index of carcinogen-induced rat mammary tumours. Phys Med Biol. 2006;51:2165–2177
  18. The National Cancer Institute, http://www.cancer.gov/dictionary/.

PII: S1350-4533(06)00261-X

doi: 10.1016/j.medengphy.2006.12.002

Medical Engineering & Physics
Volume 29, Issue 10 , Pages 1142-1148 , December 2007