Medical Engineering & Physics
Volume 29, Issue 10 , Pages 1106-1118 , December 2007

Assessment of endoleak significance after endovascular repair of abdominal aortic aneurysms: A lumped parameter model

  • B.J.B.M. Wolters

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands
    • Corresponding Author InformationCorresponding author. Tel.: +31 40 247 5398; fax: +31 40 244 7355.
  • ,
  • M. Emmer

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands
  • ,
  • M.C.M. Rutten

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands
  • ,
  • G.W.H. Schurink

      Affiliations

    • Department of Surgery, University Hospital Maastricht, The Netherlands
  • ,
  • F.N. van de Vosse

      Affiliations

    • Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands

Received 14 January 2006 ,Revised 24 November 2006 ,Accepted 25 November 2006.

References 

  1. Veith EJ, Baum RA, Ohki T, Amor M, Adiseshiah M, Blankensteijn JD, et al. Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg. 2002;35(5):1029–1035
  2. White GH, Yu W, May J, Chaufour X, Stephen MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997;4(2):152–168
  3. White GH, May J, Waugh RC, Chaufour X, Yu W. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998;5(4):305–309
  4. Baum RA, Carpenter JP, Cope C, Golden MA, Velazquez OC, Neschis DG, et al. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 2001;33(1):32–41
  5. Dias NV, Ivancev K, Malina M, Resch T, Lindblad B, Sonesson B. Intra-aneurysm sac pressure measurements after endovascular aneurysm repair: differences between shrinking, unchanged, and expanding aneurysms with and without endoleaks. J Vasc Surg. 2004;39(6):1229–1235
  6. van Marrewijk C, Buth J, Harris PL, Norgren L, Nevelsteen A, Wyatt MG. Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EU-ROSTAR experience. J Vasc Surg. 2002;35(3):461–473
  7. Schurink GW, Aarts NJ, Van Baalen JM, Kool LJ, Van Bockel JH. Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis. Br J Surg. 2000;87(1):71–78
  8. Schurink GW, van Baalen JM, Visser MJ, van Bockel JH. Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall. J Vasc Surg. 2000;31(3):501–506
  9. Skillern CS, Stevens SL, Piercy KT, Donnell RL, Freeman MB, Goldman MH. Endotension in an experimental aneurysm model. J Vasc Surg. 2002;36(4):814–817
  10. Chong CK, How TV, Gilling-Smith GL, Harris PL. Modeling endoleaks and collateral reperfusion following endovascular AAA exclusion. J Endovasc Ther. 2003;10(3):424–432
  11. Mehta M, Ohki T, Veith FJ, Lipsitz EC. All sealed endoleaks are not the same: a treatment strategy based on an ex vivo analysis. Eur J Vasc Endovasc Surg. 2001;21(6):541–544
  12. Parodi JC, Berguer R, Ferreira LM, La Mura R, Schermerhorn ML. Intra-aneurysmal pressure after incomplete endovascular exclusion. J Vasc Surg. 2001;34(5):909–914
  13. Gawenda M, Winter S, Jaschke G, Wassmer G, Brunkwall J. Endotension is influenced by aneurysm volume: experimental findings. J Endovasc Ther. 2003;10(6):1091–1096
  14. Gawenda M, Jaschke G, Winter S, Wassmer G, Brunkwall J. Endotension as a result of pressure transmission through the graft following endovascular aneurysm repair—an in vitro study. Eur J Vasc Endovasc Surg. 2003;26(5):501–505
  15. Mehta M, Veith FJ, Ohki T, Lipsitz EC, Cayne NS, Darling RC. Significance of endotension, endoleak, and aneurysm pulsatility after endovascular repair. J Vasc Surg. 2003;37(4):842–846
  16. Schurink GWH, Aarts NJM, Wilde J, van Baalen JM, Chuter TAM, Schultze Kool LJ, et al. Endoleakage after stent-graft treatment of abdominal aneurysm: implications on pressure and imaging—an in vitro study. J Vasc Surg. 1998;28(2):234–241
  17. Ellozy SH, Carroccio A, Lookstein RA, Minor ME, Sheahan CM, Juta J, et al. First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 2004;40(3):405–412
  18. Milner R, Verhagen HJM, Prinssen M, Blankensteijn JD. Noninvasive intrasac pressure measurement and the influence of type 2 and type 3 endoleaks in an animal model of abdominal aortic aneurysm. Vascular. 2004;12(2):99–105
  19. Wolters BJBM, Rutten MCM, Schurink GWH, Kose U, de Hart J, van de Vosse FN. A patient-specific computational model of fluid–structure interaction in abdominal aortic aneurysms. Med Eng Phys. 2005;27(10):871–883
  20. Westerhof N, Bosman E, de Vries CJ, Noordergraaf A. Analog studies of the human systemic arterial tree. J Biomech. 1969;2:121–143
  21. Stergiopulos N, Westerhof BE, Westerhof N. Total arterial inertance as the fourth element of the Windkessel model. Am J Physiol. 1999;276(1 Pt 2):81–88
  22. Milnor WR. Hemodynamics. 2nd ed.. Baltimore: Williams and Wilkins; 1989;
  23. Di Martino ES, Guadagni G, Fumero A, Ballerini G, Spirito R, Biglioli P, et al. Fluid–structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm. Med Eng Phys. 2001;23(9):647–655
  24. Raghavan ML, Vorp DA. Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm. J Vasc Surg. 2000;31(4):760–769
  25. Thubrikar MJ, Labrosse M, Robicsek E, Al-Soudi J, Fowler B. Mechanical properties of abdominal aortic aneurysm wall. J Med Eng Technol. 2001;25(4):133–142
  26. Idelchik IE. Handbook of hydraulic resistance. Boca Raton, FL: CRC Press, Inc.; 1994;
  27. Dayal R, Mousa A, Bernheim J, Hollenbeck S, Henderson P, Prince M, et al. Characterization of retrograde collateral (type II) endoleak using a new canine model. J Vasc Surg. 2004;40(5):985–994
  28. Diaz S, Uzieblo MR, Desai KM, Talcott MR, Bae KT, Geraghty PJ, et al. Type II endoleak in porcine model of abdominal aortic aneurysm. J Vasc Surg. 2004;40(2):339–344
  29. Mousa A, Dayal R, Bernheim L, Henderson P, Hollenbeck S, Trocciola S, et al. A canine model to study the significance and hemodynamics of type II endoleaks. J Surg Res. 2005;123(2):275–283
  30. Gawenda M, Knez P, Winter S, Jaschke G, Wassmer G, Schmitz-Rixen T, et al. Endotension is influenced by wall compliance in a latex aneurysm model. Eur J Vasc Endovasc Surg. 2004;27(1):45–50
  31. Westerhof N, Elzinga G, Sipkema P. An artificial arterial system for pumping hearts. J Appl Physiol. 1971;31(5):776–781
  32. Stergiopulos N, Meister JJ, Westerhof N. Simple and accurate way for estimating total and segmental arterial compliance: the pulse pressure method. Ann Biomed Eng. 1994;22(4):392–397
  33. Olufsen MS, Peskin CS, Kim WY, Pedersen EM, Nadim A, Larsen J. Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions. Ann Biomed Eng. 2000;28(11):1281–1299
  34. McArdle WD, Katch EL, Katch VL. Exercise physiology: energy, nutrition, and human performance. 4th ed.. Baltimore: Williams and Wilkins; 1996;

PII: S1350-4533(06)00249-9

doi: 10.1016/j.medengphy.2006.11.008

Medical Engineering & Physics
Volume 29, Issue 10 , Pages 1106-1118 , December 2007