Intra-operative evaluation of cementless hip implant stability: A prototype device based on vibration analysis

  • Maurizio Lannocca

      Affiliations

    • University of Bologna, Engineering Faculty, DEIS, Viale Risorgimento 2, 40136 Bologna, Italy
    • Tel.: +39 051 2093097.
  • ,
  • Elena Varini

      Affiliations

    • University of Bologna, Engineering Faculty, DEIS, Viale Risorgimento 2, 40136 Bologna, Italy
    • Istituti Ortopedici Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy
    • Tel.: +39 051 2093097.
    • Tel.: +39 051 6366864; fax: +39 051 6366863.
  • ,
  • Angelo Cappello

      Affiliations

    • University of Bologna, Engineering Faculty, DEIS, Viale Risorgimento 2, 40136 Bologna, Italy
    • Tel.: +39 051 2093097.
  • ,
  • Luca Cristofolini

      Affiliations

    • Istituti Ortopedici Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy
    • University of Bologna, Engineering Faculty, DIEM, Viale Risorgimento 2, 40136 Bologna, Italy
    • Corresponding Author InformationCorresponding author at: Istituti Ortopedici Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy. Tel.: +39 051 6366577/6366864/2093266; fax: +39 051 6366863/2093412.
  • ,
  • Ewa Bialoblocka

      Affiliations

    • Istituti Ortopedici Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, 40136 Bologna, Italy
    • Tel.: +39 051 6366864; fax: +39 051 6366863.

Received 6 March 2006 ,Revised 19 September 2006 ,Accepted 24 September 2006.

References 

  1. Kapandji A. Physiologie articulaire. In La Hanche. Librerie Maloine SA, 1982. Fascicule II.I.
  2. Rydell NW. Forces acting on the femoral head prosthesis. Acta Orthopaedica Scand. 1966;37(Suppl. 88):96–125
  3. Maloney WJ, Jasty M, Burke DW, O’Connor DO, Zalenski EB, Bragdon CR, et al. Biomechanical and histologic investigation of uncemented total hip arthroplasties: a study of autopsy-retrieved femurs after in vivo cycling. Clin Orthop Rel Res. 1989;249:129–140
  4. Schneider E, Kinast C, Eulenberger J, Wyder D, Eskilsson G, Perren SM. A comparative study of the initial stability of cementless hip prostheses. Clin Orthop Rel Res. 1989;248:200–209
  5. Mjöberg B. The theory of early loosening of hip prostheses. Orthopedics. 1997;20(12):1169–1175
  6. Søballe K. Hydroxyapatite ceramic coating for bone implant fixation: mechanical and histological studies in dogs. Acta Orthop Scand. 1993;(Suppl. 255):1–58
  7. Harris WH, Mulroy RD, Maloney WJ, Burke DW, Chandler HP, Zalenski EB. Intraoperative measurement of rotational stability of femoral components of total hip arthroplasty. Clin Orthop. 1991;266:119–126
  8. Brånemark R, Ohrnell LO, Skalak R, Carlsson L, Branemark PI. Biomechanical characterization of osteointegration: an experimental in vivo investigation in the beagle dog. J Orthop Res. 1998;16(1):61–69
  9. Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Rel Res. 1986;208:108–113
  10. Harman MK, Toni A, Cristofolini L, Viceconti M. Initial stability of uncemented hip stems: an in vitro protocol to measure torsional interface motion. Med Eng Phys. 1995;17:163–171
  11. Callaghan JJ, Fulghum CS, Lsisson RR, Stranne SK. The effect of femoral stem geometry on interface motion in uncemented porous-coated total hip prostheses: comparison of straight-stem and curved-stem designs. J Bone Joint Surg Am. 1992;74:839–848
  12. Nunn D, Freeman MA, Tanner KE, Bonfield W. Torsional stability of the femoral component of total hip arthroplasty: response to an anteriorly applied load. J Bone Joint Surg Am. 1989;71:452–455
  13. Heller MO, Bergmann G, Deuretzbacher G, Claes L, Haas NP, Duda GN. Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients. Clin Biomech. 2001;16:644–649
  14. Bergmann G, Graichen F, Rohlmann A. Is staircase walking a risk for the fixation of hip implants?. J Biomech. 1995;28:535–553
  15. Hodge WA, Carlson KL, Fijan RS, Burgess RG, Riley PO, Harris WH, et al. Contact pressures from an instrumented hip endoprosthesis. J Bone Joint Surg A. 1989;71:1378–1386
  16. Kotzar GM, Davy DT, Goldberg WM, Heiple KG, Berilla J, Brown RH, et al. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. J Orthop Res. 1991;9:621–633
  17. Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859–871
  18. Heller MO, Bergmann G, Deuretzbacher G, Durselen L, Pohl M, Claes L, et al. Musculo-skeletal loading conditions at the hip during walking and stair clambing. J Biomech. 2001;34:883–893
  19. Schutzer SF, Grady-Beson J, Jasty M, O’Connor DO, Bragdon C, Harris WH. Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous coated femoral components. J Arthroplasty. 1995;10:823–829
  20. Schwartz JTJ, Mayer JG, Engh CA. Femoral fractures during non-cemented total hip arthroplasty. J Bone Joint Surg [Am]. 1989;71(8):1135–1142
  21. Otani T, Witheside LA. Failure of cementless fixation of the femoral component in total hip arthroplasty. Ortho Clin North Am. 1992;23:335–346
  22. Schmidt AH, Kyle RF. Periprosthetic fractures of the femur. Ortho Clin North Am. 2002;33:143–152
  23. Goodman SB. The effects of micromotion and particulate materials on tissue differentiation: bone chamber studies in rabbits. Acta Orthop Scand. 1994;Suppl. 258:1–43
  24. Ishiguro N, Kojima T, Ito T, Saga S, Anma H, Kurokouchi K, et al. Macrophage activation and migration in interface tissue around loosening total hip arthroplasty components. J Biomed Mater Res. 1997;35:399–406
  25. Cristofolini L, Varini E, Pelgreffi I, Cappello A, Toni A. Device to measure intra-operatively the primary stability of cementless hip stems. Med Eng Phys. 2006;28(5):475–482
  26. Lowet G, Van Audekercke R, Van der Perre G, Geusens P, Dequeker J, Lammens J. The relation between resonant frequencies and torsional stiffness of long bones in vitro. Validation of a simple beam model. J Biomech. 1993;26(6):689–696
  27. Van Der Perre G, Lowet G. In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. Bone. 1996;18(Suppl. 1):29S–35S
  28. Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanuim implants during healing in the rabbit tibia. Clin Oral Impl Res. 1997;8(3):234–243
  29. Friberg B, Sennerby L, Linden B, Gröndahl K, Lekholm U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg. 1999;28:266–272
  30. Koka S. Commentary on resonance frequency analysis. Int J Prosthod. 2006;19(1):84
  31. Li PLS, Jones NB, Gregg PJ. Vibration analysis in the detection of total hip prosthetic loosening. Med Eng Phys. 1996;18(7):596–600
  32. Georgiou AP, Cunningham JL. Accurate diagnosis of hip prosthetic loosening using a vibrational technique. Clin Biomech. 2001;16:315–323
  33. Qi G, Mouchon WP, Tan TE. How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?. Clin Biomech. 2003;18:444–458
  34. Jaecques SVN, Pastrav C, Zahariuc A, Van der Perre G. Analysis of the fixation quality of cementless hip prostheses using a vibrational technique. In: Proceedings International Conference on Noise and Vibration Engineering. 2004;p. 443–456
  35. Varini E, Lannocca M, Bialoblocka E, Cappello A, Cristofolini L. Primary stability assessment in hip arthroplasty: a device based on the vibrational technique. J Biomech. 2006;39(Suppl. 1):S127

PII: S1350-4533(06)00203-7

doi: 10.1016/j.medengphy.2006.09.011

Medical Engineering & Physics
Volume 29, Issue 8 , Pages 886-894 , October 2007