Finite element models of rib as an inhomogeneous beam structure under high-speed impacts

L3 Communications, Applied Technologies Division, Jaycor, 3394 Carmel Mountain Road, San Diego, CA 92121, USA

Received 11 February 2006; received in revised form 12 May 2006; accepted 29 August 2006. published online 12 October 2006.

Abstract 

Fracture of ribs commonly occurs during blunt impacts and can lead to serious injuries or even fatality. The finite element (FE) modeling of ribs under impacts, however, is difficult due to the complex geometry, the difficulty in determining material parameters, and the amount of the computational time required. This study develops a method of modeling ribs as inhomogeneous beam structures. The geometries are reconstructed from images acquired with X-ray computed tomography. Bone material properties, orthotropic or isotropic, are determined from the CT pixel values. From the material distribution inside the cross-section, generalized classical beam formulations use to determine the local homogenized stiffness of the nodes along the rib. To compare the accuracy and efficiency of the method, detailed three-dimensional (3D) FE models of ribs are also developed. Simulations of three benchmark problems that represent different loading or impact conditions demonstrate that the beam FE model is very efficient and is at least as accurate as a very finely meshed 3D FE model. Finally, the rib FE model is used to study blunt trauma injury of animal tests under high-speed impacts. The consistency between predictions and experimental results shows that the developed rib model is a great value to study of blunt trauma caused by high-speed impacts.

Keywords: Finite element model, Blunt trauma, Ribs, Computed tomography, Animal tests

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(06)00172-X

doi:10.1016/j.medengphy.2006.08.015

Medical Engineering & Physics
Volume 29, Issue 7 , Pages 788-798, September 2007