Medical Engineering & Physics
Volume 29, Issue 3 , Pages 380-389 , April 2007

Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker's handles: Results on normal subjects

  • Majd Alwan

      Affiliations

    • Medical Automation Research Center (MARC), P.O. Box 800403, Charlottesville, VA 22908, USA
    • Corresponding Author InformationCorresponding author. Tel.: +1 434 924 2265.
  • ,
  • Alexandre Ledoux

      Affiliations

    • Department of Mechanical and Aerospace Engineering, University of Virginia, USA
  • ,
  • Glenn Wasson

      Affiliations

    • Computer Science Department, University of Virginia, USA
  • ,
  • Pradip Sheth

      Affiliations

    • Department of Mechanical and Aerospace Engineering, University of Virginia, USA
  • ,
  • Cunjun Huang

      Affiliations

    • Department of Mechanical and Aerospace Engineering, University of Virginia, USA

Received 2 February 2006 ,Revised 10 May 2006 ,Accepted 2 June 2006.

References 

  1. Fay BT, Boninger ML. The science behind mobility devices for individuals with multiple sclerosis. Med Eng Phys. 2002;24:375–383
  2. National Center for Health Statistics. Number of persons using assistive technology by age of person and type of device; 1994, http://www.cdc.gov/nchs/about/major/nhis_dis/ad292tb1.htm.
  3. Wasson G, Sheth P, Alwan M, Granata K, Ledoux A, Huang C. User intent in a shared control framework for pedestrian mobility aids. IROS. 2003;3:2962–2967
  4. Fast A, Wang FS, Aderzin RS, Cordaro MA, Ramis J, Sosner J. The instrumented walker: usage patterns and forces. Arch Phys Med Rehabil. 1995;76950:484–491
  5. Bachschmidt RA, Harris GF, Simoneau GG. Walker-assisted gait in reahbilitation: a study of biomechanics and instrumentation. IEEE Trans Neural Syst Rehabil Eng. 2001;9(1):96–105
  6. Chen LC, Chen HC, Wong MK, Tang FT, Chen RS. Temporal stride and force analysis of cane-assisted gait in people with hemiplegic stroke. Arch Phys Med Rehabil. 2001;82:43–48
  7. Aminian K, Rezakhanlou K, De Andres E, Fritsch C, Leyvraz PF, Robert P. Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty. Med Biol Eng Comput. 1999;37(6):686–691
  8. Mansfield A, Lyons GM. The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. Med Eng Phys. 2003;25:879–885
  9. Pappas IP, Keller T, Mangold S, Popovic MR, Dietz V, Morari M. A reliable gyroscope-based gait-phase detection sensor embedded in a shoe insole. IEEE Sens J. 2004;4(2):228–274
  10. Pappas IP, Popovic MR, Keller T, Dietz V, Morari M. A reliable gait phase detection system. IEEE Trans Rehabil Eng. 2001;9:113–125
  11. Skelly MM, Chizeck HJ. Real-time gait event detection for paraplegic FES walking. IEEE Trans Neural Syst Rehabil Eng. 2001;9(1):59–68
  12. Wasson G, Gunderson J, Graves S, Felder R. An assistive robotic agent for pedestrian mobility. In: International conference on autonomous agents. 2001;p. 169–173
  13. Wasson G, Gunderson J, Graves S, Felder R. Effective shared control in cooperative mobility aids. FLAIRS. 2001;509–513
  14. Sheldon RS. Quantification of human motion: gait analysis—benefits and limitations to its application to clinical problems. J Biomech. 2004;37:1869–1880
  15. Vicon612 Technical Specifications, http://www.vicon.com.
  16. Signal Processing Toolbox User's Guide, The Mathworks Inc.
  17. Alwan M, Wasson G, Sheth P, Ledoux A, Huang C. Passive derivation of basic walker-assisted gait characteristics from measured forces and moments. In: Proceedings of IEEE's 2004 Engineering in Medicine and Biology Conference (EMBC’04). San Francisco, September. 2004;
  18. Inman VT, Ralston H, Todd F. Human walking. Baltimore: Williams and Wilkins; 1981;p. 26
  19. Karcnik T. Using motion analysis data for foot-floor contact detection. Med Biol Eng Comput. 2003;41:509–512
  20. Proakis JG, Manolakis DG. Digital signal processing principles, algorithms and applications. Prentice-Hall; 1996;
  21. Samir VG, Joseph AN. Noronha, DESIGN OF IIR FILTERS, http://www.ee.vt.edu/∼jnoronha/dsp_proj2_report.pdf.

PII: S1350-4533(06)00122-6

doi: 10.1016/j.medengphy.2006.06.001

Medical Engineering & Physics
Volume 29, Issue 3 , Pages 380-389 , April 2007