Medical Engineering & Physics
Volume 28, Issue 10 , Pages 934-943 , December 2006

Planar electrochemical sensors for biomedical applications

Received 4 May 2006 ,Accepted 4 May 2006.

References 

  1. Stetter JN, Penrose WR, Sheng Y. Sensors, chemical sensors, electrochemical sensors, and ECS. J Electrochem Soc. 2003;150:S11–S16
  2. Edmonds TE. Chemical sensors. New York: Chapman and Hall; 1998;
  3. Mortimer RJ, Beech A. AC impedance characteristics of solid-state planar electrochemical carbon monoxide sensors with Nafion as solid polymer electrolyte. Electrochim Acta. 2002;47:3383–3387
  4. Lauks IR. Microfabricated biosensors and microanalytical systems for blood analysis. Acc Chem Res. 1998;31:317–324
  5. Bakker E, Telting-Diaz M . Electrochemical sensors. Anal Chem. 2002;74:2781–2800
  6. In:  Prudenziati M editors. Thick-film sensors. Amsterdam: Elsevier; 1994;
  7. White NM, Turner JD. Thick-film sensors: past, present and future. Meas Sci Technol. 1997;8:1–20
  8. Galán-Vidal CA, Muñoz J, Dominguez C, Alegret S. Glucose biosensor strip in a three electrode configuration based on composite and biocomposite materials applied by planar thick film technology. Sens Actuators B. 1998;52:257–263
  9. Alvarez-Icaza M, Bilitewski U. Mass production of biosensors. Anal. Chem. 1993;65:525A–533A
  10. Wang J, Pamidi PVA. Disposable screen printed electrodes for monitoring hydrazines. Talanta. 1995;42:463–467
  11. White NM, Turner JD. Thick-film sensors: past, present and future. Meas Sci Technol. 1997;8:1–20
  12. Albareda-Sirvent M, Merkoçi A, Alegret S. Configurations used in the design of screen-printed enzymatic biosensors. A review. Sens Actuators B. 2000;69:153–163
  13. Palchetti I, Cagnini A, Del Carlo M, Coppi C, Mascini M, Turner APF. Determination of anticholinesterase pesticides in real samples using a disposable biosensor. Anal Chim Acta. 1997;337:315–321
  14. Mulchandani A, Chen W, Mulchandani P, Wang J, Rogers KR. Biosensors for direct determination of organophosphate pesticides. Bios Bioelectron. 2001;16:225–230
  15. Lucarelli F, Kicela A, Palchetti I, Marrazza G, Mascini M . Electrochemical DNA biosensor for analysis of wastewater samples. Bioelectrochem. 2002;58:113–118
  16. Wang J, Chen Q. Enzyme microelectrode array strips for glucose and lactate. Anal Chem. 1994;66:1007–1011
  17. Cass AEG, Davis G, Francis GD, Hill HAO, Aston WJ, Higgins IJ, et al. Anal. Chem. 1984;56:667
  18. Higgins I.J., Hill H.A.O. and Plotkin E.V. 1985. US Patent 4545382.
  19. Lam Y-Z, Atkinson J. Disposable screen-printed biosensor for transcutaneous oxygen measurement. Meas Sci Technol. 2002;13:2074–2081
  20. Laschi S, Fránek M, Mascini M. Screen-printed electrochemical immunosensors for PCB detection. Electroanalysis. 2000;12:1293–1298
  21. Marrazza G, Chianella I, Mascini M. Disposable DNA electrochemical biosensors for environmental monitoring. Anal Chim Acta. 1999;389:297–307
  22. Lucarelli F, Palchetti I, Marrazza G, Mascini M. Electrochemical DNA biosensor as a screening tool for the detection of toxicants in water and wastewater samples. Talanta. 2002;56:949–957
  23. Bergveld P. The future of biosensors. Sens Actuators A. 1996;56:65–67
  24. Göpel W. New materials and transducers for chemical sensors. Sens Actuators B. 1994;18/19:1–21
  25. Novotny I, Breternitz V, Ivanic R, Knedlik Ch , Tvarozek V, Spiess L, et al. Thin film microelectrode arrays for electrochemical biosensors. In: 44rd International Scientific Colloquium. Technical University of Ilmenau. 1999;
  26. Tvarozek V, Novotny I, Rehacek V, Ivanic R, Mika F. Thin film electrode chips for microelectrochemical sensors. NEXUS Res News. 1998;1:15–17
  27. Wallgren K, Sotiropoulos S. Electrochemistry of planar solid-state amperometric devices based on Nafion® and polybenzimidazole solid polymer electrolytes. Electrochim Acta. 2001;46:1523–1532
  28. Harsáni G. Polymer films in sensor application. USA: Techn. Publishing Company; 1995;
  29. Photolithography 2000 on http://www.dbanks.demon.co.uk/ueng/plith.html.
  30. Biittgenbach S. Mikromeckanic. Germany: Taubner tudienbucher Stuttgart; 1991;
  31. Shaw KA, Zhang ZL, MacDonald NC. SCREAM I: a single mask, single-crystal silicon, reactive ion etching process for microelectromechanical structures. Sens Actuators A. 1994;40:63–70
  32. Makino E, Shibata T, Yamada Y . Micromachining of fine ceramics by photolithography. Sens Actuators A. 1999;75:278–288
  33. Thielicke E, Obermeier E. Microactuators and their technologies. Mechatronics. 2000;10:431–455
  34. Rogers KR. Principles of affinity biosensors. Mol. Biotechnol. 2000;14:109–129
  35. Prasada Rao K, Hussain Md O, Reddy KTR, Reddy PS, Uthanna S, Naidu BS, et al. Characterization of two-source evaporated cadmium zinc telluride thin films. Opt Mater. 1996;5:63K–68K
  36. Vossen JL, Kern W. Thin film processes. New York, San Francisco, London: Academic Press; 1978;
  37. Sberveglieri G, Anchisini R, Murri R, Ercoli C, Pinto N. An Al2O3 sensor for low humidity content: Characterization by impedance spectroscopy. Sens Actuators B: Chem. 1996;32:1–5
  38. Fleischer M, Seth M, Kohl C-D, Meixner H. Study of surface modification at semiconducting Ga2O3 thin film sensors for enhancement of the sensitivity and selectivity. Sens Actuators B: Chem. 1996;36:290–296
  39. Pfeiffer D, Möller B, Klimes N, Szeponik J, Fischer S. Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology. Biosens Bioelectr. 1997;12:539–550
  40. Middelhoek S, Bellekom AA, Dauderstadt U, French PJ, in ’t Hout SR, Kindt W, et al. Silicon sensors. Meas. Sci. Technol. 1995;6:1641–1658
  41. Sharmat A, Rogers KR. Biosens Meas Sci Technol. 1994;5:461–472
  42. Lakard B, Herlem G, de Labachelerie M, Daniau W, Martin G, Jeannot J-C, et al. Miniaturized pH biosensors based on electrochemically modified electrodes with biocompatible polymers. Biosens Bioelectr. 2004;19:595–606
  43. Revzin AF, Sirkar K, Simonian A, Pishko MV. Glucose, lactate, and pyruvate biosensor arrays based on redox polymer/oxidoreductase nanocomposite thin-films deposited on photolithographically patterned gold microelectrodes. Sens Actuators B. 2002;81:359–368
  44. Alden JA, Booth J, Compton RG, Dryfe RA, Sanders GHW. Diffusional mass transport to microband electrodes of practical geometries: a simulation study using the strongly implicit procedure. J Electroanal Chem. 1995;389:45–54
  45. Niwa O, Morita M, Tabei H . Electrochemical behaviour of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency. Anal Chem. 1990;62:447–452
  46. Štulík K, Amatore C, Holub K, Marecek V, Kutner W. Microelectrodes. Definitions, characterisation, and applications. Pure Appl Chem. 2000;72:1483–1492
  47. Beriet C, Pletcher D. A further microelectrode study of the influence of electrolyte concentration on the kinetics of redox couples. J Electroanal Chem. 1994;375:213–218
  48. Bixler JW, Bond AM. Amperometric detection of picomole samples in a microdisk electrochemical flow-jet cell with dilute supporting electrolyte. Anal Chem. 1986;58:2859–2863
  49. Niwa O, Xu Y, Halsall HB, Heineman WR. Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay. Anal Chem. 1993;65:1559–1563
  50. Male KB, Luong JHT. Chiral analysis of neurotransmitters using cyclodextrin-modified capillary electrophoresis equipped with microfabricated interdigitated electrodes. J Chromatogr A. 2003;1003:167–178
  51. Janata J, Bezegh A . Chemical sensors. Anal Chem. 1998;60:62R–74R
  52. Senillou A, Jaffrezic N, Martelet C, Cosnier S. A laponite clay-poly(pyrrole-pyridinium) matrix for the fabrication of conductimetric microbiosensors. Anal Chim Acta. 1999;401:117–124
  53. Laureyn W, Nelis D, Van Gerwen P, Baert K, Hermans L, Magnée R, et al. Nanoscaled interdigitated titanium electrodes for impedimetric biosensing. Sens Actuators B. 2000;68:360–370
  54. Lillie G, Payne P, Vadgama P . Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing. Sens Actuators B. 2001;78:249–256
  55. Van Gerwen P, Laureyn W, Huyberechts G, De Beeck MO, Baert K, Suls J, et al. Nanoscaled interdigitated electrode arrays for biochemical sensors. Sens Actuators B. 1998;49:73–80
  56. Finot E, Bourillot E, Meunier-Prest R, Lacroute Y, Legay G, Cherkaoui-Malki M, et al. Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor. Ultramicroscopy. 2003;97:441–449
  57. Patel SV, DiBattista M, Gland JL, Schwank JW. Survivability of a silicon-based microelectronic gas-detector structure for high-temperature flow applications. Sens Actuators B. 1996;37:27–35
  58. Perdomo J, Hinkers H, Sundermeier C, Seifert W, Martínez Morell O, Knoll M. Miniaturized real-time monitoring system for -lactate and glucose using microfabricated multi-enzyme sensors. Biosens Bioelectr. 2000;15:515–522
  59. Van Hal REG, Eijkel JCT, Bergveld P. A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters. Sens Actuators B. 1995;24:201–205
  60. Bergveld P. Development of an Ion-sensitive solid-state device for neurophysiological measurements. IEEE Trans Biomed Eng. 1970;17:70
  61. Reinhoudt DN. Durable chemical sensors based on field-effect transistors. Sens Actuators B. 1995;24/25:197–200
  62. Chudy M, Wróblewski W, Dybko A, Brzózka Z. Multi-ion analysis based on versatile sensor head. Sens Actuators B. 2001;78:320–325
  63. Stauthamer WPRV, Engbersen JFJ, Verboom W, Reinhoudt DN. Influence of plasticizer on the selectivity of nitrate-sensitive CHEMFETs. Sens Actuators B. 1994;17:197–201
  64. Pijanowska DG, Torbicz W. pH-ISFET based urea biosensor. Sens Actuators B. 1997;44:370–376
  65. Luppa PB, Sokoll LJ, Chan DW. Immunosensors – principles and applications to clinical chemistry. Clin Chim Acta. 2001;314:1–26
  66. Sergeyeva TA, Soldatkin AP, Rachkov AE, Tereschenko MI, Piletsky SA, El'skaya AV. β-Lactamase label-based potentiometric biosensor for a α2-interferon detection. Anal Chim Acta. 1999;390:73–81
  67. Selvanayagam ZE, Neuzil P, Gopalakrishnakone P, Sridhar U, Singh M, Ho LC. An ISFET-based immunosensor for the detection of – Bungarotoxin. Biosens Bioelectron. 2002;17:821–826
  68. Maboudian R. Surface processes in MEMS technology. Surf Sci Rep. 1998;30:207–269
  69. Vinet F, Chaton P, Fouillet Y . Microarrays and microfluidic devices: miniaturized systems for biological analysis. Microelectr Eng. 2002;61:41–47
  70. Manz A, Graber N, Widmer HM. Miniaturized total chemical analysis systems: a novel concept for chemical sensing. Sens Actuators B. 1990;244–248
  71. Kutter JP. Current developments in electrophoretic and chromatographic separation methods on microfabricated devices. TrAC Trends Anal Chem. 2000;19:352–363
  72. Mouradian M. Lab-on-a-chip: Applications in proteomics. Curr Opin Chem Biol. 2002;6:51–56
  73. Ehrfeld W. Electrochemistry and microsystems. Electrochim Acta. 2003;48:2857–2868

PII: S1350-4533(06)00102-0

doi: 10.1016/j.medengphy.2006.05.006

Medical Engineering & Physics
Volume 28, Issue 10 , Pages 934-943 , December 2006