« Previous
Next »
Medical Engineering & Physics
Volume 28, Issue 10
, Pages 934-943
, December 2006
Planar electrochemical sensors for biomedical applications
References
- . Sensors, chemical sensors, electrochemical sensors, and ECS. J Electrochem Soc. 2003;150:S11–S16
- . Chemical sensors. New York: Chapman and Hall; 1998;
- . AC impedance characteristics of solid-state planar electrochemical carbon monoxide sensors with Nafion as solid polymer electrolyte. Electrochim Acta. 2002;47:3383–3387
- . Microfabricated biosensors and microanalytical systems for blood analysis. Acc Chem Res. 1998;31:317–324
- . Electrochemical sensors. Anal Chem. 2002;74:2781–2800
- In: Prudenziati M editors. Thick-film sensors. Amsterdam: Elsevier; 1994;
- . Thick-film sensors: past, present and future. Meas Sci Technol. 1997;8:1–20
- . Glucose biosensor strip in a three electrode configuration based on composite and biocomposite materials applied by planar thick film technology. Sens Actuators B. 1998;52:257–263
- . Mass production of biosensors. Anal. Chem. 1993;65:525A–533A
- . Disposable screen printed electrodes for monitoring hydrazines. Talanta. 1995;42:463–467
- . Thick-film sensors: past, present and future. Meas Sci Technol. 1997;8:1–20
- . Configurations used in the design of screen-printed enzymatic biosensors. A review. Sens Actuators B. 2000;69:153–163
- . Determination of anticholinesterase pesticides in real samples using a disposable biosensor. Anal Chim Acta. 1997;337:315–321
- . Biosensors for direct determination of organophosphate pesticides. Bios Bioelectron. 2001;16:225–230
- . Electrochemical DNA biosensor for analysis of wastewater samples. Bioelectrochem. 2002;58:113–118
- . Enzyme microelectrode array strips for glucose and lactate. Anal Chem. 1994;66:1007–1011
- Anal. Chem. 1984;56:667
- Higgins I.J., Hill H.A.O. and Plotkin E.V. 1985. US Patent 4545382.
- . Disposable screen-printed biosensor for transcutaneous oxygen measurement. Meas Sci Technol. 2002;13:2074–2081
- . Screen-printed electrochemical immunosensors for PCB detection. Electroanalysis. 2000;12:1293–1298
- . Disposable DNA electrochemical biosensors for environmental monitoring. Anal Chim Acta. 1999;389:297–307
- . Electrochemical DNA biosensor as a screening tool for the detection of toxicants in water and wastewater samples. Talanta. 2002;56:949–957
- . The future of biosensors. Sens Actuators A. 1996;56:65–67
- . New materials and transducers for chemical sensors. Sens Actuators B. 1994;18/19:1–21
- Thin film microelectrode arrays for electrochemical biosensors. In: 44rd International Scientific Colloquium. Technical University of Ilmenau. 1999;
- . Thin film electrode chips for microelectrochemical sensors. NEXUS Res News. 1998;1:15–17
- . Electrochemistry of planar solid-state amperometric devices based on Nafion® and polybenzimidazole solid polymer electrolytes. Electrochim Acta. 2001;46:1523–1532
- . Polymer films in sensor application. USA: Techn. Publishing Company; 1995;
- Photolithography 2000 on http://www.dbanks.demon.co.uk/ueng/plith.html.
- . Mikromeckanic. Germany: Taubner tudienbucher Stuttgart; 1991;
- . SCREAM I: a single mask, single-crystal silicon, reactive ion etching process for microelectromechanical structures. Sens Actuators A. 1994;40:63–70
- . Micromachining of fine ceramics by photolithography. Sens Actuators A. 1999;75:278–288
- . Microactuators and their technologies. Mechatronics. 2000;10:431–455
- . Principles of affinity biosensors. Mol. Biotechnol. 2000;14:109–129
- Characterization of two-source evaporated cadmium zinc telluride thin films. Opt Mater. 1996;5:63K–68K
- . Thin film processes. New York, San Francisco, London: Academic Press; 1978;
- . An Al2O3 sensor for low humidity content: Characterization by impedance spectroscopy. Sens Actuators B: Chem. 1996;32:1–5
- . Study of surface modification at semiconducting Ga2O3 thin film sensors for enhancement of the sensitivity and selectivity. Sens Actuators B: Chem. 1996;36:290–296
- . Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology. Biosens Bioelectr. 1997;12:539–550
- Silicon sensors. Meas. Sci. Technol. 1995;6:1641–1658
- . Biosens Meas Sci Technol. 1994;5:461–472
- Miniaturized pH biosensors based on electrochemically modified electrodes with biocompatible polymers. Biosens Bioelectr. 2004;19:595–606
- . Glucose, lactate, and pyruvate biosensor arrays based on redox polymer/oxidoreductase nanocomposite thin-films deposited on photolithographically patterned gold microelectrodes. Sens Actuators B. 2002;81:359–368
- . Diffusional mass transport to microband electrodes of practical geometries: a simulation study using the strongly implicit procedure. J Electroanal Chem. 1995;389:45–54
- . Electrochemical behaviour of reversible redox species at interdigitated array electrodes with different geometries: consideration of redox cycling and collection efficiency. Anal Chem. 1990;62:447–452
- . Microelectrodes. Definitions, characterisation, and applications. Pure Appl Chem. 2000;72:1483–1492
- . A further microelectrode study of the influence of electrolyte concentration on the kinetics of redox couples. J Electroanal Chem. 1994;375:213–218
- . Amperometric detection of picomole samples in a microdisk electrochemical flow-jet cell with dilute supporting electrolyte. Anal Chem. 1986;58:2859–2863
- . Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay. Anal Chem. 1993;65:1559–1563
- . Chiral analysis of neurotransmitters using cyclodextrin-modified capillary electrophoresis equipped with microfabricated interdigitated electrodes. J Chromatogr A. 2003;1003:167–178
- . Chemical sensors. Anal Chem. 1998;60:62R–74R
- . A laponite clay-poly(pyrrole-pyridinium) matrix for the fabrication of conductimetric microbiosensors. Anal Chim Acta. 1999;401:117–124
- Nanoscaled interdigitated titanium electrodes for impedimetric biosensing. Sens Actuators B. 2000;68:360–370
- . Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing. Sens Actuators B. 2001;78:249–256
- Nanoscaled interdigitated electrode arrays for biochemical sensors. Sens Actuators B. 1998;49:73–80
- Performance of interdigitated nanoelectrodes for electrochemical DNA biosensor. Ultramicroscopy. 2003;97:441–449
- . Survivability of a silicon-based microelectronic gas-detector structure for high-temperature flow applications. Sens Actuators B. 1996;37:27–35
- . Miniaturized real-time monitoring system for -lactate and glucose using microfabricated multi-enzyme sensors. Biosens Bioelectr. 2000;15:515–522
- . A novel description of ISFET sensitivity with the buffer capacity and double-layer capacitance as key parameters. Sens Actuators B. 1995;24:201–205
- . Development of an Ion-sensitive solid-state device for neurophysiological measurements. IEEE Trans Biomed Eng. 1970;17:70
- . Durable chemical sensors based on field-effect transistors. Sens Actuators B. 1995;24/25:197–200
- . Multi-ion analysis based on versatile sensor head. Sens Actuators B. 2001;78:320–325
- . Influence of plasticizer on the selectivity of nitrate-sensitive CHEMFETs. Sens Actuators B. 1994;17:197–201
- . pH-ISFET based urea biosensor. Sens Actuators B. 1997;44:370–376
- . Immunosensors – principles and applications to clinical chemistry. Clin Chim Acta. 2001;314:1–26
- . β-Lactamase label-based potentiometric biosensor for a α2-interferon detection. Anal Chim Acta. 1999;390:73–81
- . An ISFET-based immunosensor for the detection of – Bungarotoxin. Biosens Bioelectron. 2002;17:821–826
- . Surface processes in MEMS technology. Surf Sci Rep. 1998;30:207–269
- . Microarrays and microfluidic devices: miniaturized systems for biological analysis. Microelectr Eng. 2002;61:41–47
- . Miniaturized total chemical analysis systems: a novel concept for chemical sensing. Sens Actuators B. 1990;244–248
- . Current developments in electrophoretic and chromatographic separation methods on microfabricated devices. TrAC Trends Anal Chem. 2000;19:352–363
- . Lab-on-a-chip: Applications in proteomics. Curr Opin Chem Biol. 2002;6:51–56
- . Electrochemistry and microsystems. Electrochim Acta. 2003;48:2857–2868
PII: S1350-4533(06)00102-0
doi: 10.1016/j.medengphy.2006.05.006
© 2006 IPEM. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Engineering & Physics
Volume 28, Issue 10
, Pages 934-943
, December 2006
