Medical Engineering & Physics
Volume 29, Issue 3 , Pages 291-297 , April 2007

Biomedical sensor using thick film technology for transcutaneous oxygen measurement

Received 18 November 2005 ,Revised 30 March 2006 ,Accepted 31 March 2006.

References 

  1. Sircar SS. The oxygen-carrying flask: a representational transform of the oxygen dissociation curve of haemoglobin. Adv Physiol Educ. 1994;266:33–35
  2. Application Notes from Radiometer and Hewlett Packard, Transcutaneous pO2/pCO2 monitoring in neonatology, 1994.
  3. Graziani LJ, Spitzer AR, Mitchell DG, Merton DA, Stanley C, Robinson N, et al. Mechanical ventilation in preterm infants: neurosonographic and developmental studies. Pediatrics. 1992;90:515–522
  4. Sinex JE. Pulse oximetry: principles and limitations. Am J Emerg Med. 1999;17(1):59–67
  5. Hay WW, Brockway JM, Eyzaguirre M. Neonatal pulse oximetry: accuracy and reliability. Pediatrics. 1989;83(5):717–722
  6. Topfer ML. Thick-film microelectronics—fabrication, design and application. Litton Educational Publishing Inc.; 1971;[Chapter 2], ISBN 0442285647 m
  7. Clark LC. Monitor and control of blood and tissue oxygen tensions. Trans Am Soc Art Int Org. 1956;2:41–57
  8. Southampton Electrochemistry Group. Instrumental methods in electrochemistry. Ellis Horwood Ltd.; 1985;p. 149, ISBN 0134720938 pbk
  9. Lam YZ, Atkinson JK. Transient and steady-state responses of thick-film oxygen sensors. Measurement. 2003;34:355–361
  10. Lubbers DW. Theoretical basis of the transcutaneous blood gas measurements. Crit Care Med. 1981;9(10):721–733
  11. Monaco F, Nickerson BG, McQuitty JC. Continuous transcutaneous oxygen and carbon dioxide monitoring in the pediatric ICU. Crit Care Med. 1982;10:765–766
  12. Karagounis V, Liu L, Liu CC. A thick-film multiple component cathode three-electrode oxygen sensor. IEEE Trans Biomed Eng. 1986;33(BME-2):108–112
  13. Lide DR. CRC handbook of chemistry and physics 2000–2001: a ready reference book of chemical and physical data. CRC Press; 2000;
  14. DuPont™ Nafion® PFSA Membranes N-117 Perfluorosulfonic Acid Polymer product information, NAE101, 2002.
  15. Lam Y-Z, Atkinson J. Disposable screen-printed biosensor for transcutaneous oxygen measurement. Meas Sci Technol. 2002;13:2074–2081
  16. Lam YZ, Atkinson JK. Screen-printed transcutaneous oxygen sensor employing polymer electrolytes. IEE Med Biol Comput Eng J. 2003;41:456–463
  17. Shwachman H, Mahmoodian A, Neff RK. The sweat test: sodium and chloride values. J Pediatr. 1981;98:576–578

PII: S1350-4533(06)00080-4

doi: 10.1016/j.medengphy.2006.03.010

Medical Engineering & Physics
Volume 29, Issue 3 , Pages 291-297 , April 2007