Rate-responsive pacing based on the atrio-ventricular conduction time: Comparison of different algorithms

Received 13 July 2005 ,Revised 26 November 2005 ,Accepted 29 November 2005.

References 

  1. Schaldach M. Electrotherapy of the heart. Berlin: Springer-Verlag; 1992;
  2. Werner J, Hexamer M, Meine M, Lemke B. Restoration of cardio-circulatory regulation by rate-adaptive pacemaker systems. IEEE Trans Biomed Eng. 1999;46:1057–1064
  3. Guyton AC. Textbook of medical physiology. Philadelphia, PA: Saunders; 1986;pp. 169–170
  4. Irnich W, Conrady J. A new principle of rate adaptive pacing in patients with sick sinus syndrome. PACE. 1986;11:1823–1828
  5. Irnich W. Frequenzadaptierender Herzschrittmacher. European Patent No. 255,899; 1988.
  6. Baker RG. A-V responsive rate adaptive pacemaker. U.S. Patent No. 4,856,524; 1989.
  7. Ruiter JH, de Boer H, Begemann MJS, van Mechelen R. The AR interval as exercise indicator: a new option for rate adaptation in single and dual chamber pacing. PACE. 1990;13:1656–1665
  8. Stoop G, Begemann M. Rate controlled pacemaker system using AR interval for rate control. European Patent Specification No. 91,914,576.3; 1994.
  9. Hexamer M, Drewes C, Meine M, Kloppe A, Weckmüller J, Mügge A, et al. Rate-responsive pacing using the atrio-ventricular conduction time: design and test of a new algorithm. Med Biol Eng Comp. 2004;42(5):688–697
  10. Nollo G, Del Greco M, Ravelli F, Disertori M. Evidence of low- and high-frequency oscillations in human AV interval variability: evaluation with spectral analysis. Am J Physiol. 1994;267:1410–1418
  11. Ljung L. System identification: theory for the user. Upper Saddle River, NJ: Prentice Hall; 1999;
  12. Ismer B, von Knorre GH, Voss W. Exercise induced sympathetic influences do not change interatrial conduction times in VDD and DDD pacing. PACE. 1996;19:1786–1790
  13. Morari M, Zafiriou E. Robust process control. Englewood Cliffs, NJ: Prentice Hall; 1989;
  14. Hexamer M, Meine M, Kloppe C, Kloppe A, Muegge A, Werner J. The dromotropic pacemaker: system analysis and design considerations. Biomed Tech. 2004;49:300–305
  15. Hexamer M. Analyse und Synthese frequenzadaptiver Herzschrittmacher. At (Automatisierungstechnik) 2005;53:445–53 (in German).
  16. Hexamer M, Meine M, Kloppe A, Werner J. Rate-responsive pacing based on the atrio-ventricular conduction time. IEEE Trans Biomed Eng. 2002;49:185–195
  17. Insulander P, Juhlin-Dahnfelt A, Freyschuss U, Vallin H. Electrophysiological effects of mental stress in healthy subjects. J Electrocardiol. 2003;36:301–309

PII: S1350-4533(05)00255-9

doi: 10.1016/j.medengphy.2005.11.012

Medical Engineering & Physics
Volume 28, Issue 9 , Pages 894-904 , November 2006