Medical Engineering & Physics
Volume 28, Issue 8 , Pages 816-826, October 2006

Analysis of the point mechanical impedance of fingerpad in vibration

National Institute for Occupational Safety & Health, 1095 Willowdale Road, MS-2027, Morgantown, WV 26505, USA

Received 3 January 2005; received in revised form 23 November 2005; accepted 30 November 2005. published online 20 January 2006.

Abstract 

Biodynamic responses of the finger–hand–arm system, such as apparent mass and mechanical impedance, characterize the relationship between the motion of the finger–hand–arm system and the dynamic force acting on the driving point, and they are useful for vibration exposure assessment. In the present study, a two-dimensional finite element (FE) model has been proposed to simulate the biodynamic responses of the fingerpad in vibration tests. The fingernail was supported by the rigid ground while the fingerpad was activated by a vibration probe. The fingertip model is composed of skin, subcutaneous tissue, bone, and nail. The soft tissues (i.e., skin and subcutaneous tissues) were assumed to be non-linearly elastic and linearly viscoelastic. The FE model was applied to predict the effects of pre-indentation of the vibration probe onto the fingerpad, the damping of the soft tissues, and probe mass on the magnitude and phase angle of the mechanical impedance and the apparent mass, as measured in the vibration tests. The model predictions showed that the probe mass has non-negligible effects on the measured biodynamic responses in the vibration tests. In order to determine “true” biodynamic responses of the finger–hand–arm system, the mass effects have to be cancelled using an appropriate approach. The present analysis provided a theoretical explanation, from a biomechanical point-of-view, for the inconsistencies in the published experimental data for the biodynamic responses of fingerpad.

Keywords: Finite element model, Soft tissue mechanics, Fingertip, Mechanical impedance, Vibration

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(05)00254-7

doi:10.1016/j.medengphy.2005.11.013

Medical Engineering & Physics
Volume 28, Issue 8 , Pages 816-826, October 2006