Medical Engineering & Physics
Volume 28, Issue 7 , Pages 682-693 , September 2006

Evaluation and improvement of the efficiency of the Seidel humeral nail by numerical–experimental analysis of the bone-implant contact

  • Fabio Giudice

      Affiliations

    • DIIM, Department of Industrial and Mechanical Engineering, University of Catania, Viale A. Doria 6, 95125 Catania, Italy
    • Corresponding Author InformationCorresponding author. Tel.: +39 095 7382418; fax: +39 095 330258.
  • ,
  • Guido La Rosa

      Affiliations

    • DIIM, Department of Industrial and Mechanical Engineering, University of Catania, Viale A. Doria 6, 95125 Catania, Italy
  • ,
  • Tullio Russo

      Affiliations

    • Department of Orthopaedics and Trauma, P.O. Vittorio Emanuele, Via Plebiscito 628, 95124 Catania, Italy
  • ,
  • Roberto Varsalona

      Affiliations

    • Department of Orthopaedics and Trauma, P.O. Vittorio Emanuele, Via Plebiscito 628, 95124 Catania, Italy

Received 22 September 2004 ,Revised 25 October 2005 ,Accepted 31 October 2005.

References 

  1. Wu CC. Humeral shaft non-union treated by a Seidel interlocking nail with a supplementary staple. Clin Orthop Relat Res. 1996;326:203–208
  2. Holm CL. Management of humeral shaft fractures: Fundamental nonoperative techniques. Clin Orthop. 1970;71:132–139
  3. Sarmiento A, Kinman PB, Galvin EG, Schmitt RH, Phillips JG. Functional bracing of fractures of the shaft of the humerus. J Bone Joint Surg. 1977;59A:596–601
  4. Hunter SG. The closed treatment of fractures of the humeral shaft. Clin Orthop. 1982;164:192–198
  5. Varley GW. The Seidel locking humeral nail: the Nottingham experience. Injury. 1995;26:155–157
  6. Svend-Hansen H, Skettrup M, Rathcke MW. Complications using the Seidel intramedullary humeral nail: outcome in 31 patients. Acta Orthop Belgica. 1998;64:291–295
  7. Bell MJ, Beauchamp CG, Kellam JK, McMurtry RY. The results of plating humeral shaft fractures in patients with multiple injuries. J Bone Joint Surg. 1985;67B:293–296
  8. Brunback RJ, Bosse MJ, Poka A, Burgess AR. Intramedullary stabilisation of humeral shaft fractures in patients with multiple trauma. J Bone Joint Surg. 1986;68A:960–969
  9. Bleeker WA, Nijsten MW, Duis HJ. Treatment of humeral shaft fractures related to associated injuries: a retrospective study of 237 patients. Acta Orthop Scand. 1991;62:148–153
  10. Foster RJ, Dixon GL, Bach AW, Appleyard RW, Green TM. Internal fixation of fractures and non-unions of the humeral shaft. J Bone Joint Surg. 1985;67A:857–864
  11. Dabezies EJ, Banta CJ, Murphy CP, D’Ambrosia RD. Plate fixation of the humeral shaft for acute fractures, with or without radial nerve injuries. J Orthop Trauma. 1992;6:10–13
  12. Wu CC, Shih CH. Treatment of non-union of the shaft of the humerus: comparison of plates and Seidel interlocking nails. Can J Surg. 1992;35:661–665
  13. Lin J. Treatment of humeral shaft fractures with humeral locked nail and comparison with plate fixation. J Trauma. 1998;44:859–864
  14. Lin J, Hou SM, Hang YS. Treatment of humeral shaft delayed unions and nonunions with humeral locked nails. J Trauma. 2000;48:695–703
  15. Stern PJ, Mattingly DA, Pomeroy DL, Zenni EJ, Kreig JK. Intramedullary fixation of humeral shaft fractures. J Bone Joint Surg. 1984;66A:639–646
  16. Watanabe RS. Intramedullary fixation of complicated fractures of the humeral shaft. Clin Orthop. 1993;292:255–263
  17. Lin J, Hou SM, Inoue N, Chao EYS, Hang YS. Anatomic considerations of locked humeral nailing. Clin Orthop Relat Res. 1999;368:247–254
  18. Pritchett JW. Delayed union of humeral shaft fractures treated by closed flexible intramedullary nailing. J Bone Joint Surg. 1985;67:715–718
  19. Ingmar AM, Waters DA. Locked intramedullary nailing of humeral shaft fractures. J Bone Joint Surg. 1994;76B:23–29
  20. McKee MD, Miranda MA, Riemer BL. Management of humeral non-union after the failure of locking intramedullary nailing. J Trauma. 1996;48:695–703
  21. Rupp RE, Chrissos MG, Ebraheim NA. The risk of neurovascular injury with distal locking screws of humeral intramedullary nails. Orthopedics. 1996;19:593–595
  22. Seidel H. Humeral locking nail: a preliminary report. Orthopedics. 1989;12:219–226
  23. Howmedica . Humeral locking nail system. Howmedica, Osteonics Corp.; 1998;
  24. Riemer BL, Butterfield SL, D’Ambrosia R, Kellam J. Seidel intramedullary nailing of humeral diaphyseal fractures: a preliminary report. Orthopedics. 1991;14:239–246
  25. Habernek H, Orthner E. A locking nail for fractures of the humerus. J Bone Joint Surg. 1991;73B:651–653
  26. Tomè JL, Carsi B, Garcia-Fernandes C, Marco F, Stern LLD. Treatment of pathologic fractures of the humerus with Seidel nailing. Clin Orthop Relat Res. 1998;350:51–55
  27. Thomsen NO, Mikkelsen JB, Svendsen RN, Skovgaard N, Jensen CH, Jorgensen U. Interlocking nailing of humeral shaft fractures. J Orthop Sci. 1998;3:199–203
  28. Schratz W, Worsdorfer O, Klockner C, Gotze C. Intramedullary nailing of humeral shaft fractures. Der Unfallchirurg. 1998;101:12–17
  29. Cheng J, Lau PY. Distal fracture with hypertrophic non-union: a complication of Seidel humeral nail. Injury. 1997;28:223–226
  30. Bain GI, Sandow MJ, Howie DW. Treatment of humeral shaft fractures with the Seidel intramedullary nail. Aust N Z J Surg. 1996;66:156–158
  31. Riemer BL, Foglesong ME, Burke CJ, Butterfield SL. Complications of Seidel intramedullary nailing of narrow diameter humeral diaphyseal fractures. Orthopedics. 1994;17:19–29
  32. Kellam JK. The biomechanical and anatomical basis of the Seidel humeral locking nail. Abstracts of the advanced course in intramedullary locking nailing. Toronto; 1991.
  33. Schopfer A, Hearn TC, Malisano L, Powell JN, Kellam JF. Comparison of torsional strength of humeral intramedullary nailing: a cadaveric study. J Orthop Trauma. 1994;8:414–421
  34. Eveleigh RJ. A review of biomechanical studies of intramedullary nails. Med Eng Phys. 1995;17:323–331
  35. Healy W, White GM, Mick CA, Brooker AF, Weiland AJ. Nonunion of the humeral shaft. Clin Orthop. 1987;219:206–213
  36. Zimmerman MC, Waite AM, Deehan M, Tovey J, Oppenheim W. A biomechanical analysis of four humeral fracture fixation systems. J Orthop Trauma. 1994;8:233–239
  37. Wu CC, Shih CH, Chen WJ, Tai CL. Staple augmentation to treat a humeral non-union after failed Seidel locking nail. Arch Orthop Trauma Surg. 1998;118:42–44
  38. Rho JY, Kuhn-Spearing L, Zioupos P. Mechanical properties and the hierarchical structure of bone. Med Eng Phys. 1998;20:92–102
  39. Keyak JH, Meagher JM, Skinner HB, Mote CD. Automated three-dimensional finite element modelling of bone: a new method. J Biomed Eng. 1990;12:389–397
  40. Marom SA, Linden M. Computer aided stress analysis of long bones utilizing computer tomography. J Biomech. 1990;23:399–404
  41. Reilly DT, Burstein AH. The elastic and ultimate properties of compact bone tissue. J Biomech. 1975;8:393–405
  42. Ashman RB, Cowin SC, van Buskirk WC, Rice JC. A continuous wave technique for the measurement of the elastic properties of cortical bone. J Biomech. 1984;17:349–361
  43. Rho JY, Hobatho MC, Ashman RB. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys. 1995;17:347–355
  44. MSC. MSC.Marc volume A: theory and user information—Version 2001. MSC.Software Corp.; 2001;
  45. Liggings AB. The practical application of Fuji Prescale pressure-sensitive film. In:  Shelton JC,  Orr JF editor. Optical measurement methods in biomechanics. London: Chapman and Hall; 1997;p. 173–189
  46. Williams PR, Shewring D. Use of an elastic intramedullary nail in difficult humeral fractures. Injury. 1998;29:661–670
  47. Schwarz N, Posch E. Seidel interlocking nailing for healing problems in humeral shaft fractures. Injury. 1995;26:13–15

PII: S1350-4533(05)00228-6

doi: 10.1016/j.medengphy.2005.10.012

Medical Engineering & Physics
Volume 28, Issue 7 , Pages 682-693 , September 2006