Medical Engineering & Physics
Volume 28, Issue 6 , Pages 560-567, July 2006

Direct digital lateral cephalometry: The effects of JPEG compression on image quality

  • N.A. Wenger

      Affiliations

    • Department of Oral Health, West Block, Norfolk and Norwich University Hospital, Colney Lane, Norwich, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 1603 288085.
  • ,
  • D.H.T.K. Tewson

      Affiliations

    • Department of Oral Health, West Block, Norfolk and Norwich University Hospital, Colney Lane, Norwich, UK
  • ,
  • F. McDonald

      Affiliations

    • GKT Dental Institute, Kings College, London, UK

Received 4 March 2005; received in revised form 31 August 2005; accepted 28 September 2005. published online 15 November 2005.

Abstract 

Objectives

This study used an aluminium test object to assess the effect of the Joint Photographics Expert Group (JPEG) compression algorithm, on direct digital cephalometric image quality.

Methods

The aluminium block of 15 steps, with 20 holes in each step was radiographed in a Planmeca Proline 2002 digital cephalometric machine with Dimaxis2 software. Six different JPEG compression ratios were used to capture the cephalometric images. These ratios were 60%, 70%, 80%, 90%, TOP QUALITY JPEG (TQJPEG 98%) and TIFF (uncompressed). The images were taken at 68kV and 12mA with a 7s exposure.

Six experienced observers viewed the monitor displayed images, which were presented randomly. This was repeated one month later. The number of holes detected by each observer was plotted against each compression ratio. Intra-observer and inter-observer reproducibility was calculated using the Mann–Whitney U-test.

Differences between the compression ratios were assessed using a Kruskal–Wallis one-way analysis of variance.

Results

When comparing intra-observer reproducibility, it was found that there were only four of 36 comparisons that showed a statistically significant difference (Observer 1: 60% (P=0.004), TQJPEG (P=0.019); Observer 2: TIFF (P=0.005); Observer 3: 90% (P=0.007)).

Statistically, there was no significant difference with inter-observer reproducibility.

There was no statistically significant difference between the image quality obtained from each compression ratio.

Conclusions

The results showed that JPEG compression does not have any effect on the perceptibility of landmarks in the aluminium test object used in this study.

Keywords: Direct digital lateral cephalometry, JPEG compression, Image quality

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(05)00213-4

doi:10.1016/j.medengphy.2005.09.010

Medical Engineering & Physics
Volume 28, Issue 6 , Pages 560-567, July 2006