« Previous
Next »
Medical Engineering & Physics
Volume 28, Issue 2
, Pages 122-133
, March 2006
Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method
References
- . Numerical solution of flow in mechanical heart valves: grid resolution and the assumption of the flow summary. ASME J Biomech Eng. 2003;85:881–892
- . The fluid mechanics of the aortic valve. J Fluid Mech. 1969;35(Part 4):721–735
- . Flow patterns around heart valves: a numerical method. J Comp Phys. 1972;10:252–271
- . Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding. J Biomech. 1994;27(4):391–402
- . Numerical analysis of three-dimensional björk–shiley valvular flow in an aorta. ASME J Biomech Eng. 1997;119:45–51
- . An initial parametric study on fluid flow through bileaflet mechanical heart valves using computational fluid dynamics. J Eng Med. 1994;208:63–72
- . A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results. J Biomech. 1996;29(5):609–618
- . Three-dimensional study of the e_ect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve. Med Eng Phys. 1997;19(5):235–241
- . Computational approach for probing the flow through artificial heart devices. ASME J Biomech Eng. 1997;119:452–460
- . Analysis of 3D transient blood flow passing through and artificial aortic valve by Lattice–Boltzmann methods. J Biomech. 1998;31:453–462
- . Numerical simulation of mechanical mitral heart valve closure. Ann Biomed Eng. 2001;29:665–676
- . A numerical simulation of mechanical heart valve closure fluid dynamics. J Biomech. 2002;35:881–892
- . Unsteady e_ects on the flow across tilting disk valves. ASME J Biomech Eng. 2002;124:21–29
- De Hart J, “Fluid–structure interaction in the aortic heart valve,” Ph.D. thesis, Eindhoven University of Technology, Eindhoven, The Netherlands, 2002.
- . Two dimensional fluid structure interaction simulation of bileaflet mechanical heart vave flow dynamics. J Heart Valve Dis. 2003;12(6):772–780
- . A numerical simulation of mechanical heart valve closure fluid dynamics. J Biomech. 2002;35(7):881–892
- . A couples fluid structure finite element method of the aortic valve and root. J Heart Valve Dis. 2003;12(6):781–789
- . Dynamic impact analysis of a bileaflet mechanical heart valve. J Heart Valve Dis. 2003;12(1):102–109
- . Finite strip method. CRC Press LLC; 1998;
- . A numerical analysis of the backflow between the leaflets of the St. Jude mechanical cardiac valve prostheses. J Biomed Eng. 1991;24:333–341
- . In vitro closing behavior of Bjork-Shiley, St. Jude and Hancock heart valve prostheses in relation to in vitro recorded aortic valve closure. J Biomech. 1982;15:841–848
- . Text book of medical physiology. 4th ed.. Philadelphia: W.B. Saunders Co.; 1971;p. 153
- . Fluid mechanics. New York: McGraw Hill, Series in Mechanical Engineering; 1999;
- . Dynamic behavior analysis of mechanical monoleaflet heart valve prostheses in the opening phase. J Biomech Eng. 1993;115:348–349
- . Impact dynamics. New York: Wiley; 1982;p. 57–70
- . Transient behavior analysis of a mechanical monoleaflet heart valve prostheses in closing phase. J Biomech Eng. 1994;116(4):452–459
- . Numerical methods for engineering application. New York: Marcel Dekker; 1993;p. 325–359
- . Numerical simulation of opening process in a process in a bileaflet mechanical heart valve under pulstile flow condition. J Heart Valve Dis. 2003;12(2):245–255
- . Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulstile flow. J Heart Valve Dis. 2000;9(5):721–725
- . The closing behaviour of Medtronic Hall mechanical heart valve. ASAIO J. 1994;40(3):M702–M706
- . Fluid mechanics of heart valve. Annu Rev Biomed Eng. 2004;6:08.1–08.32
- http://www.mech-eng.leeds.ac.uk/res-group/biomedical/bio_images/sj1.gif.
PII: S1350-4533(05)00079-2
doi: 10.1016/j.medengphy.2005.03.013
© 2005 IPEM. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Medical Engineering & Physics
Volume 28, Issue 2
, Pages 122-133
, March 2006
