Medical Engineering & Physics
Volume 28, Issue 3 , Pages 276-289, April 2006

An integrated tool for the diagnosis of voice disorders

Dpt. of Ingeniería de Circuitos y Sistemas, Universidad Politécnica de Madrid, Ctra. Valencia, Km. 7, 28031 Madrid, Spain

Received 27 April 2004; received in revised form 21 February 2005; accepted 6 April 2005. published online 10 June 2005.

Abstract 

A PC-based integrated aid tool has been developed for the analysis and screening of pathological voices. With it the user can simultaneously record speech, electroglottographic (EGG), and videoendoscopic signals, and synchronously edit them to select the most significant segments. These multimedia data are stored on a relational database, together with a patient's personal information, anamnesis, diagnosis, visits, explorations and any other comment the specialist may wish to include.

The speech and EGG waveforms are analysed by means of temporal representations and the quantitative measurements of parameters such as spectrograms, frequency and amplitude perturbation measurements, harmonic energy, noise, etc. are calculated using digital signal processing techniques, giving an idea of the degree of hoarseness and quality of the voice register.

Within this framework, the system uses a standard protocol to evaluate and build complete databases of voice disorders.

The target users of this system are speech and language therapists and ear nose and throat (ENT) clinicians. The application can be easily configured to cover the needs of both groups of professionals.

The software has a user-friendly Windows style interface. The PC should be equipped with standard sound and video capture cards. Signals are captured using common transducers: a microphone, an electroglottograph and a fiberscope or telelaryngoscope.

The clinical usefulness of the system is addressed in a comprehensive evaluation section.

Keywords: Speech disorder database, Diagnostic aid system, Voice and endoscopic image database, Assessment protocol

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1350-4533(05)00078-0

doi:10.1016/j.medengphy.2005.04.014

Medical Engineering & Physics
Volume 28, Issue 3 , Pages 276-289, April 2006